A Power-Line Communication System Governed by Loop Resonance for Photovoltaic Plant Monitoring

Sensors (Basel). 2022 Nov 26;22(23):9207. doi: 10.3390/s22239207.

Abstract

Within this paper, a PLC system that takes advantage of the loop resonance of an entire DC-PV string configured as a circular signal path is developed and implemented. Low cost and extremely simple transceivers intended to be installed within each PV module of a string have been designed and successfully tested. In addition, an anti-saturation coil has been conceived to avoid saturation of the core when the entire DC current of the string flows through it. Bi-directional half-duplex communication was successfully executed with up to a 1 MHz carrier frequency (150 kbps bitrate), using a simple ASK modulation scheme. The transmission and reception performance are presented, along with the overall system cost in comparison to the previous literature.

Keywords: low cost; monitoring; power-line communication (PLC); resonance.

MeSH terms

  • Communication*
  • Equipment Design