Deep Learning-Assisted Measurements of Photoreceptor Ellipsoid Zone Area and Outer Segment Volume as Biomarkers for Retinitis Pigmentosa

Bioengineering (Basel). 2023 Dec 6;10(12):1394. doi: 10.3390/bioengineering10121394.

Abstract

The manual segmentation of retinal layers from OCT scan images is time-consuming and costly. The deep learning approach has potential for the automatic delineation of retinal layers to significantly reduce the burden of human graders. In this study, we compared deep learning model (DLM) segmentation with manual correction (DLM-MC) to conventional manual grading (MG) for the measurements of the photoreceptor ellipsoid zone (EZ) area and outer segment (OS) volume in retinitis pigmentosa (RP) to assess whether DLM-MC can be a new gold standard for retinal layer segmentation and for the measurement of retinal layer metrics. Ninety-six high-speed 9 mm 31-line volume scans obtained from 48 patients with RPGR-associated XLRP were selected based on the following criteria: the presence of an EZ band within the scan limit and a detectable EZ in at least three B-scans in a volume scan. All the B-scan images in each volume scan were manually segmented for the EZ and proximal retinal pigment epithelium (pRPE) by two experienced human graders to serve as the ground truth for comparison. The test volume scans were also segmented by a DLM and then manually corrected for EZ and pRPE by the same two graders to obtain DLM-MC segmentation. The EZ area and OS volume were determined by interpolating the discrete two-dimensional B-scan EZ-pRPE layer over the scan area. Dice similarity, Bland-Altman analysis, correlation, and linear regression analyses were conducted to assess the agreement between DLM-MC and MG for the EZ area and OS volume measurements. For the EZ area, the overall mean dice score (SD) between DLM-MC and MG was 0.8524 (0.0821), which was comparable to 0.8417 (0.1111) between two MGs. For the EZ area > 1 mm2, the average dice score increased to 0.8799 (0.0614). When comparing DLM-MC to MG, the Bland-Altman plots revealed a mean difference (SE) of 0.0132 (0.0953) mm2 and a coefficient of repeatability (CoR) of 1.8303 mm2 for the EZ area and a mean difference (SE) of 0.0080 (0.0020) mm3 and a CoR of 0.0381 mm3 for the OS volume. The correlation coefficients (95% CI) were 0.9928 (0.9892-0.9952) and 0.9938 (0.9906-0.9958) for the EZ area and OS volume, respectively. The linear regression slopes (95% CI) were 0.9598 (0.9399-0.9797) and 1.0104 (0.9909-1.0298), respectively. The results from this study suggest that the manual correction of deep learning model segmentation can generate EZ area and OS volume measurements in excellent agreement with those of conventional manual grading in RP. Because DLM-MC is more efficient for retinal layer segmentation from OCT scan images, it has the potential to reduce the burden of human graders in obtaining quantitative measurements of biomarkers for assessing disease progression and treatment outcomes in RP.

Keywords: biomarkers; deep learning; photoreceptor ellipsoid zone area; photoreceptor outer segment volume; retinitis pigmentosa.