Real time monitoring of temperature of a micro proton exchange membrane fuel cell

Sensors (Basel). 2009;9(3):1423-32. doi: 10.3390/s90301423. Epub 2009 Mar 3.

Abstract

Silicon micro-hole arrays (Si-MHA) were fabricated as a gas diffusion layer (GDL) in a micro fuel cell using the micro-electro-mechanical-systems (MEMS) fabrication technique. The resistance temperature detector (RTD) sensor was integrated with the GDL on a bipolar plate to measure the temperature inside the fuel cell. Experimental results demonstrate that temperature was generally linearly related to resistance and that accuracy and sensitivity were within 0.5 °C and 1.68×10(-3)/°C, respectively. The best experimental performance was 9.37 mW/cm(2) at an H(2)/O(2) dry gas flow rate of 30/30 SCCM. Fuel cell temperature during operation was 27 °C, as measured using thermocouples in contact with the backside of the electrode. Fuel cell operating temperature measured in situ was 30.5 °C.

Keywords: GDL; MEMS; RTD sensor; Si-MHA; micro fuel cell.