High-Resolution Monitoring of Scour Using a Novel Fiber-Optic Distributed Temperature Sensing Device: A Proof-of-Concept Laboratory Study

Sensors (Basel). 2023 Apr 5;23(7):3758. doi: 10.3390/s23073758.

Abstract

Scour events can severely change the characteristics of streams and impose detrimental hazards on any structures built on them. The development of robust and accurate devices to monitor scour is therefore essential for studying and developing mitigation strategies for these adverse consequences. This technical note introduces a novel scour-monitoring device that utilizes new advances in the fiber-optic distributed temperature sensing (FO-DTS) technology. The novel FO-DTS scour-monitoring device utilizes the differential thermal responses of sediment, water, and air media to a heating event to accurately identify the locations of the interfaces between them. The performance of the device was tested in a laboratory flume under flow conditions with water velocities ranging from 0 m/s to 0.16 m/s. In addition, the effect of the measurement duration on the device's measurement accuracy was also investigated. The FO-DTS scour-monitoring device managed to detect the sediment-water and water-air interfaces with average absolute errors of 1.60 cm and 0.63 cm, respectively. A measurement duration of fewer than 238 s was sufficient to obtain stable measurements of the locations of the sediment-water and water-air interfaces for all the tested flow conditions.

Keywords: distributed temperature sensing; monitoring; scour; sediment transport; water depth sensing.