Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1999 2
2000 1
2005 1
2008 1
2014 1
2015 1
2016 3
2017 1
2018 1
2020 2
2021 2
2022 1
2023 4
2024 2

Text availability

Article attribute

Article type

Publication date

Search Results

22 results

Results by year

Filters applied: . Clear all
Page 1
Drilling characteristics and properties analysis of fiber reinforced polymer composites: A comprehensive review.
Jagadeesh P, Mavinkere Rangappa S, Suyambulingam I, Siengchin S, Puttegowda M, Binoj JS, Gorbatyuk S, Khan A, Doddamani M, Fiore V, Cuadrado MMM. Jagadeesh P, et al. Heliyon. 2023 Mar 13;9(3):e14428. doi: 10.1016/j.heliyon.2023.e14428. eCollection 2023 Mar. Heliyon. 2023. PMID: 36967975 Free PMC article. Review.
Usually, the FRP composites possess a heterogeneous nature because of their multi-layered structure, hybridization, and the presence of multi-phase materials. Hence, common problems like delaminations, fuzzing, buckling, cracking, matrix and fiber burning occur during the …
Usually, the FRP composites possess a heterogeneous nature because of their multi-layered structure, hybridization, and the presence of mult …
Lipid Peroxidation in Subretinal Fluid: Some Light on the Prognosis Factors.
Bosch-Morell F, García-Gen E, Mérida S, Penadés M, Desco C, Navea A. Bosch-Morell F, et al. Biomolecules. 2021 Mar 30;11(4):514. doi: 10.3390/biom11040514. Biomolecules. 2021. PMID: 33808427 Free PMC article.
We collected 65 SRF samples from consecutive patients during scleral buckling surgery in rhegmatogenous retinal detachment (RRD) eyes. In addition to a complete ophthalmic evaluation, we studied the refractive status, evolution time, and the number of detached retinal quad …
We collected 65 SRF samples from consecutive patients during scleral buckling surgery in rhegmatogenous retinal detachment (RRD) eyes …
Prediction of Critical Buckling Load on Open Cross-Section Columns of Flax/PLA Green Composites.
Jiao-Wang L, Puerta-Hueso S, Pedroche D, Santiuste C. Jiao-Wang L, et al. Polymers (Basel). 2022 Nov 23;14(23):5095. doi: 10.3390/polym14235095. Polymers (Basel). 2022. PMID: 36501490 Free PMC article.
The present work aims to analyze the buckling behavior of nonlinear elastic columns with different open cross-sections and slenderness ratios to verify the limits of the modified Ludwick law to predict the critical buckling load. ...Moreover, the theoretical estimat …
The present work aims to analyze the buckling behavior of nonlinear elastic columns with different open cross-sections and slendernes …
Multimethod analysis of three rotary instruments produced by electric discharge machining technology.
Silva EJNL, Ajuz NC, Martins JNR, Antunes BR, Lima CO, Vieira VTL, Braz-Fernandes FM, Versiani MA. Silva EJNL, et al. Int Endod J. 2023 Jun;56(6):775-785. doi: 10.1111/iej.13915. Epub 2023 Apr 25. Int Endod J. 2023. PMID: 36942476

ProTaper Gold showed the highest torque to failure (p < .001) and HyFlex EDM had the lowest buckling resistance (p < .001). Mean percentages of unprepared canal areas ranged from 20.4% to 25.7% in the mesial canals, and from 20.8% to 26.2% in the distal canal, with n

ProTaper Gold showed the highest torque to failure (p < .001) and HyFlex EDM had the lowest buckling resistance (p < .001). Mea

Recovery course of persistent posterior subretinal fluid after successful repair of rhegmatogenous retinal detachment.
Mansour AM, López-Guajardo L, Belotto S, Lima LH, Charbaji AR, Schwartz SG, Wu L, Smiddy WE, Ascaso J, Jürgens I, Foster RE, Elnahry AG, Sinawat S, Pinilla I, Pérez-Salvador García E, Suarez Leoz M, Olivier Pascual N, Zago Ribeiro L, Arroyo Castillo R, Navea A, Kadayifcilar S, Ellabban AA, Rey A, Mansour HA, Tripathy K, Kozak I, Uwaydat SH, Valero MS, Cobo-Soriano R, Díaz-Barreda MD, Monje Fernández L, González Del Valle F, López Liroz I, Vazquez Cruchaga E, Fonollosa A, Esteban Floria O, Relimpio Lopez MI, Shah G, Wingelaar MJ, Ravani R, Donate-López J, Rubio Velázquez E, Parodi M; Collaborative Postsurgical Residual Subretinal Fluid Study Group. Mansour AM, et al. Eur J Ophthalmol. 2023 Oct 30:11206721231210693. doi: 10.1177/11206721231210693. Online ahead of print. Eur J Ophthalmol. 2023. PMID: 37901895

RESULTS: One hundred and three cases had persistent SRF after pars plana vitrectomy, scleral buckling, or pneumatic retinopexy. By univariate analysis, SRF resolution time correlated positively with the number of retinal breaks (p < 0.001) and with increased myopia (p =

RESULTS: One hundred and three cases had persistent SRF after pars plana vitrectomy, scleral buckling, or pneumatic retinopexy. By un …
Bending, buckling and torsional resistance of rotary and reciprocating glide path instruments.
Lopes WSP, Vieira VTL, Silva EJNL, Silva MCD, Alves FRF, Lopes HP, Pires FR. Lopes WSP, et al. Int Endod J. 2020 Dec;53(12):1689-1695. doi: 10.1111/iej.13385. Epub 2020 Sep 5. Int Endod J. 2020. PMID: 32767775

RESULTS: WOGG had the lowest bending resistance, whilst RP had the highest bending resistance (P < 0.05). RP also had the highest buckling resistance, and WOGG had the lowest (P < 0.05). PG had intermediate results regarding bending and buckling resistance, wi

RESULTS: WOGG had the lowest bending resistance, whilst RP had the highest bending resistance (P < 0.05). RP also had the highest buck

Face Damage Growth of Sandwich Composites under Compressive Loading: Experiments, Analytical and Finite Element Modeling.
Kinawy M, Rubino F, Canale G, Citarella R, Butler R. Kinawy M, et al. Materials (Basel). 2021 Sep 24;14(19):5553. doi: 10.3390/ma14195553. Materials (Basel). 2021. PMID: 34639950 Free PMC article.
Panel with fibers oriented transversally to the compressive load showed an opening (Mode-I) propagation of a delamination, while the panel with fibers parallel to the load showed shear (Mode-II) propagation. The static load such to determine local buckling of the composite …
Panel with fibers oriented transversally to the compressive load showed an opening (Mode-I) propagation of a delamination, while the panel w …
Active destabilization of base pairs by a DNA glycosylase wedge initiates damage recognition.
Kuznetsov NA, Bergonzo C, Campbell AJ, Li H, Mechetin GV, de los Santos C, Grollman AP, Fedorova OS, Zharkov DO, Simmerling C. Kuznetsov NA, et al. Nucleic Acids Res. 2015 Jan;43(1):272-81. doi: 10.1093/nar/gku1300. Epub 2014 Dec 17. Nucleic Acids Res. 2015. PMID: 25520195 Free PMC article.
Modeling of the base eversion with energy decomposition suggested that the wedge destabilizes the intrahelical base primarily through buckling both surrounding base pairs. Replacement of oxoG with abasic (AP) site rescued the activity, and calculations suggested that wedge …
Modeling of the base eversion with energy decomposition suggested that the wedge destabilizes the intrahelical base primarily through buc
To flat or not to flat? Exploring the impact of flat-side design on rotary instruments using a comprehensive multimethod investigation.
Silva EJNL, Alcalde MP, Martins JNR, Vieira VTL, Vivan RR, Duarte MAH, Belladonna FG, Braz-Fernandes FM, Versiani MA. Silva EJNL, et al. Int Endod J. 2023 Oct;56(10):1301-1315. doi: 10.1111/iej.13960. Epub 2023 Aug 18. Int Endod J. 2023. PMID: 37594701
No statistical difference was observed between tested instruments regarding angle of rotation (p = .437), maximum bending (p = .152) and buckling load (p = .411). Preparation protocols using flat and nonflat instruments did not show any statistically significant difference …
No statistical difference was observed between tested instruments regarding angle of rotation (p = .437), maximum bending (p = .152) and …
22 results