A Useful Method for the Practice of Pneumatic Retinopexy: Slit-Lamp Laser Photocoagulation through the Gas Bubble

J Pers Med. 2023 Apr 27;13(5):741. doi: 10.3390/jpm13050741.

Abstract

This study aimed to demonstrate the laser retinopexy method through the gas bubble under a slit-lamp biomicroscope using a wide-field contact lens to treat rhegmatogenous retinal detachment (RRD) with pneumatic retinopexy (PR) and report its anatomical and functional results. This single-center, retrospective case series included RRD patients treated with PR using sulfur hexafluoride (SF6). The demographics, preoperative factors, and anatomical and functional outcomes were collected from the patient files. The single-procedure success rate of PR at postoperative 6th months was 70.8% (17/24 eyes), and the final success rate after secondary surgeries was 100%. The BCVA was better in the successful PR eyes at postoperative 3rd (p = 0.011) and 6th month (p = 0.016) than in failed eyes. No single preoperative factor was associated with PR success. The single-procedure success rate of PR using the laser retinopexy method through the gas bubble with a wide-field contact lens system seems comparable to the PR literature.

Keywords: laser retinopexy; pneumatic retinopexy; retinal detachment; sulfur hexafluoride; wide-field contact lens.

Grants and funding

This research received no external funding.