Breath Alcohol Test Results in Equine Veterinarians after Performing an Abdominal Ultrasound with Ethanol

Vet Sci. 2023 Mar 14;10(3):222. doi: 10.3390/vetsci10030222.

Abstract

Transcutaneous abdominal ultrasonography using alcohol saturation is used in the diagnostic workup of a variety of conditions in horses. The duration of the examination and the amount of alcohol used in each case may vary depending on several factors. The aim of this study is to describe the breath alcohol test results obtained by veterinarians performing abdominal ultrasound on horses. Six volunteers were enrolled, after written consent, and a Standardbred mare was used for the whole study protocol. Each operator performed a total of 6 ultrasounds by pouring the ethanol solution from a jar or by spray application, for a duration of 10, 30, and 60 min. An infrared breath alcohol analyzer was used immediately after completing the ultrasonography and at 5-min intervals until a negative result was obtained. Positive results were obtained for 0-60 min after the procedure. A statistically significant difference was found between the groups that used more than 1000 mL, 300-1000 mL, and less than 300 mL of ethanol. No significant differences were observed between the type of ethanol administration and the time of exposure. Based on this study, equine vets who perform ultrasound on horses can test positive at the breath alcohol test for up to 60 min following ethanol exposure.

Keywords: alcohol inhalation; breathalyser; horse; ultrasonography.

Grants and funding

This research project was supported by the University of Sydney’s Murray Bain Horse fund.