[Flash electroretinography and pattern-type visual evoked potentials in early glaucoma]

Klin Oczna. 1998;100(5):285-8.
[Article in Polish]

Abstract

Purpose: The aim of this prospective study was to evaluate diagnostic sensitivity of flash-erg, oscillatory potentials (OPs), and pattern-visual evoked potentials (pVEP) in early glaucoma.

Material and methods: Erg, OPs and pVEP were registered in 416 eyes primary open angle glaucoma (120 eyes), normal tension glaucoma (137), ocular hypertension (74), glaucoma-like discs (86) in age-matched groups, by Tomey 400.

Results: There were no statistically significant differences between parameters of flash-erg and pVEP of examined population and control group. Significant reduction in OPs amplitude in NTG patients were found.

Conclusions: Flash erg and pVEP have low diagnostic value in early glaucoma. OPs could be useful in scientific research on pathogenesis of glaucomatous neuropathy.

Publication types

  • English Abstract

MeSH terms

  • Adult
  • Age Factors
  • Aged
  • Electroretinography / methods*
  • Evoked Potentials, Visual*
  • Glaucoma / diagnosis*
  • Humans
  • Middle Aged
  • Ocular Hypertension / diagnosis
  • Time Factors