Management of recurrent, complex instability of the elbow with a hinged external fixator

J Bone Joint Surg Br. 1998 Nov;80(6):1031-6. doi: 10.1302/0301-620x.80b6.8536.

Abstract

We have treated 16 patients with recurrent complex elbow instability using a hinged external fixator. All patients had instability, dislocation or subluxation of the ulnohumeral joint. The injuries were open in eight patients and were associated with 20 other fractures and five peripheral nerve injuries. Two patients had received initial treatment from us; 14 had previously had a mean of 2.1 unsuccessful surgical procedures (1 to 6). The fixator was applied at a mean of 4.8 weeks (0 to 9) after the injury and remained on the elbow for a mean of 8.5 weeks (6 to 11). After treatment we found the mean range of flexion-extension to be 105 degrees (65 to 140). At a final follow-up of 23 months (14 to 40), the mean Morrey score was 84 (49 to 96): this translated into one poor, three fair, ten good and two excellent results. Complications included one fractured humeral pin, one temporary palsy of the radial nerve, one recurrent instability, one wound infection, one severe pin-track infection and one patient with reflex sympathetic dystrophy. Although technically demanding, the use of the fixator is an important advance in the management of recurrent complex elbow instability after failure of conventional treatment.

MeSH terms

  • Adult
  • Aged
  • Elbow Injuries*
  • External Fixators*
  • Female
  • Follow-Up Studies
  • Humans
  • Joint Dislocations / surgery
  • Joint Instability / surgery*
  • Male
  • Middle Aged
  • Postoperative Complications
  • Range of Motion, Articular
  • Recurrence
  • Reoperation