A simple scintigraphic method for continuous monitoring of gastric emptying

Eur J Nucl Med. 1993 Mar;20(3):260-3. doi: 10.1007/BF00170009.

Abstract

A new and simple scintigraphic method for the measurement of gastric emptying was developed and validated. The test meal consists of 200 g potato mash mixed with 0.5 g Dowex 2X8 particles (mesh 20-50) labelled with 37 MBq (1 mCi) technetium-99m. After ingestion of the meal, sequential dynamic 15-s anteroposterior exposures in the supine position are obtained for 90 min. A second recording sequence of 20 min is added after a 30-min interval. The results can be displayed as immediate cine-replay, as time-activity diagrams and/or as activity retention values. Complicated mathematical fittings are not necessary. The method lends itself equally to the testing of in- and outpatients.

MeSH terms

  • Anion Exchange Resins*
  • Duodenum / diagnostic imaging*
  • Female
  • Food*
  • Gastric Emptying*
  • Humans
  • Male
  • Radionuclide Imaging
  • Resins, Synthetic
  • Solanum tuberosum
  • Stomach / diagnostic imaging*
  • Technetium*
  • Time Factors

Substances

  • Anion Exchange Resins
  • Resins, Synthetic
  • Dowex
  • Technetium