Detection of myocardial ischemia by 31P magnetic resonance spectroscopy during handgrip exercise

Circulation. 1994 Apr;89(4):1709-16. doi: 10.1161/01.cir.89.4.1709.

Abstract

Background: The metabolic changes of myocardial ischemia in patients with coronary artery disease assessed by 31P magnetic resonance spectroscopy (MRS) have been reported previously. A significant decrease in the ratio of phosphocreatine (PCr) to ATP during handgrip exercise in a group of patients with severe coronary artery disease has been demonstrated. However, there are no reports at present that directly compare cardiac 31P MRS data with exercise 201Tl myocardial scintigraphy, now established as one of the most important clinical methods to assess myocardial ischemia. The purpose of this study was to investigate whether 31P MRS with handgrip exercise testing is able to detect myocardial ischemia, demonstrated by exercise 201Tl scintigraphy.

Methods and results: Twenty-seven patients with severe stenosis of the left anterior descending coronary artery (> or = 75%) and 11 normal control subjects composed the present study. Patients were divided into two groups on the basis of exercise 201Tl scintigraphy: a reversible 201Tl defect group (RD[+]) who demonstrated redistribution at the late image and a fixed 201Tl defect group (RD[-]). While lying supine within the magnet, subjects performed handgrip exercise at 30% of maximal force once in every two cardiac cycles. 31P MR spectra were collected before and during handgrip exercise. Data were corrected for the saturation factor. ANOVA revealed significant differences among the three groups with respect to the mean +/- SD PCr/ATP ratio at rest (control, 1.85 +/- 0.28 > RD(+), 1.60 +/- 0.19 > RD(-), 1.24 +/- 0.30; P < .05). The PCr/ATP ratio decreased significantly from 1.60 +/- 0.19 at rest to 0.96 +/- 0.28 during exercise (P < .001) in the RD(+) group (n = 15). However, in the RD(-) group (n = 12), the ratio did not change significantly during handgrip exercise (1.24 +/- 0.30 at rest versus 1.19 +/- 0.28 during exercise). Similarly, the ratio did not change in the control group (n = 11) (1.85 +/- 0.28 at rest versus 1.90 +/- 0.23 during exercise).

Conclusions: Contrary to normal subjects or patients with fixed thallium defects, the PCr/ATP ratio was significantly altered by exercise in patients with reversible thallium defects. These results suggest that 31P MRS with handgrip exercise testing is a sensitive method for detecting myocardial ischemia.

Publication types

  • Comparative Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adenosine Triphosphate / metabolism
  • Coronary Disease / diagnosis*
  • Coronary Disease / diagnostic imaging
  • Exercise
  • Exercise Test
  • Female
  • Heart / diagnostic imaging
  • Humans
  • Magnetic Resonance Spectroscopy
  • Male
  • Middle Aged
  • Myocardial Ischemia / diagnosis*
  • Myocardial Ischemia / diagnostic imaging
  • Myocardium / metabolism*
  • Phosphocreatine / metabolism
  • Sensitivity and Specificity
  • Thallium Radioisotopes
  • Tomography, Emission-Computed, Single-Photon

Substances

  • Thallium Radioisotopes
  • Phosphocreatine
  • Adenosine Triphosphate