Determination of N-nitrosodimethylamine in nonfat dry milk: collaborative study

J Assoc Off Anal Chem. 1984 Mar-Apr;67(2):232-6.

Abstract

Ten laboratories participated in a collaborative study of a method for the determination of N-nitrosodimethylamine (NDMA) in nonfat dry milk. NDMA is eluted with dichloromethane from a mixture of Celite, acidic sulfamic acid, and nonfat dry milk (all packed in a chromatography column), concentrated in a Kuderna -Danish concentrator, and finally analyzed by a GC-thermal energy analyzer technique. Ten samples were studied: 6 were naturally contaminated (NDMA levels 0.38-3.56 ppb) and 4 were spiked with known levels (0.96 and 3.2 ppb) of NDMA. The coefficients of variation (CV) of the complete data for the naturally contaminated samples (excluding the 2 samples containing the lowest levels) were 8.5% and 22.5% for repeatability and reproducibility, respectively. The corresponding CVs for the spiked samples were 14.4% and 20.4%, respectively. The percent recoveries of the added NDMA in the spiked samples (at the 2 levels indicated above) were 101.6 +/- 3.2 (omitting 1 outlier) and 95 +/- 2.1, respectively. The method has been adopted official first action.

MeSH terms

  • Animals
  • Cattle
  • Chromatography, Gas / methods
  • Dimethylnitrosamine / analysis*
  • Food Additives / analysis*
  • Food Preservation*
  • Milk / analysis*

Substances

  • Food Additives
  • Dimethylnitrosamine