Clinical Outcome of the Type A Acute Aortic Dissection Repair Using the "Tailored Stand-Up Collar" Technique

Ann Thorac Cardiovasc Surg. 2024;30(1). doi: 10.5761/atcs.oa.23-00214.

Abstract

Purpose: Achieving a secure anastomosis and complete hemostasis is essential for surgically treating type A acute aortic dissection (TAAAD). This study assessed the clinical feasibility of "tailored stand-up collar (TSC)" technique for constructing the distal stump.

Methods: We enrolled 68 patients who underwent ascending aortic repair for TAAAD. Patients were categorized according to the technique for distal stump construction: conventional (C) group using only a felt strip (32 cases); post-aortotomy (P) group, with a Hydrofit-felt strip attached after aortotomy (18 cases), and TSC group, where a Hydrofit-felt strip attached during cooling (18 cases). Pre-operative characteristics, procedural profiles, and post-operative outcomes were evaluated.

Results: The pre-operative characteristics were identical among the groups. The durations of cardiopulmonary bypass, hemostasis, and surgery were significantly shorter in the P and TSC groups. The duration of open distal in the TSC group (21 min) was significantly shorter than the other two groups. Post-operative additional procedures were not required for the TSC group and their post-operative hospital stay was significantly shorter (47.1% of patients were discharged within 2 weeks).

Conclusion: The TSC technique would be practical because of its high reproducibility in terms of ease of use, shorter anastomotic time, and secure hemostasis.

Keywords: Hydrofit; distal stump construction; tailored stand-up collar technique; type A acute aortic dissection.

MeSH terms

  • Acute Disease
  • Adult
  • Aged
  • Aortic Aneurysm / diagnostic imaging
  • Aortic Aneurysm / surgery
  • Aortic Aneurysm, Thoracic / diagnostic imaging
  • Aortic Aneurysm, Thoracic / surgery
  • Aortic Dissection* / diagnostic imaging
  • Aortic Dissection* / surgery
  • Blood Vessel Prosthesis Implantation* / adverse effects
  • Blood Vessel Prosthesis Implantation* / instrumentation
  • Feasibility Studies*
  • Female
  • Humans
  • Length of Stay*
  • Male
  • Middle Aged
  • Operative Time
  • Postoperative Complications / etiology
  • Retrospective Studies
  • Time Factors
  • Treatment Outcome