Influence of Diabetes Mellitus and Universal Adhesive Application Mode on the Bond Strength of Composite Resin to Dentine

J Clin Exp Dent. 2024 Apr 1;16(4):e416-e425. doi: 10.4317/jced.61328. eCollection 2024 Apr.

Abstract

Background: The aim of the current study was to evaluate the influence of diabetes mellitus and the mode of applying a universal adhesive on the shear bond strength of composite resin to dentin.

Material and methods: Forty teeth were extracted from diabetic individuals who had been living with diabetes for a period of 5 to 15 years. These forty teeth were divided into two groups: twenty molars from patients with type 1 diabetes and twenty molars from patients with type 2 diabetes. The remaining twenty sound human molars were collected from non-diabetic patients. The collected teeth were assigned into 3 groups, and each group was further divided into 2 subgroups. Group A (n = 20): non-diabetic (ND) where sub group IA: Universal adhesive applied in the total-etch mode (n = 10) and sub group IIA: Universal adhesive applied in the self-etch mode (n = 10). Group B (n = 20): diabetic type 1 (D1) where sub group IB: Universal adhesive applied in the total-etch mode (n = 10) and sub group IIB: Universal adhesive applied in the self-etch mode (n = 10). Group C (n = 20): diabetic type 2 (D2). Where Sub group IC: Universal adhesive applied in the total-etch mode (n = 10) and sub group IIC: Universal adhesive applied in the self-etch mode (n = 10). A Teflon mold measuring 3mm in diameter was attached to the dentin surface, used to build Filtek Z550 to a height of 3mm. The specimens were fixed to the universal testing to measure shear bond strength.

Results: There was a statistically significant difference of Mean ±SD of shear bond strength among the three tested groups. In group A, the Mean ±SD were (21.710 ± 0.638), it was decreased in group B to (14.626 ± 0.726) and group C to (17.740 ± 0.668). Subgroup I had lower shear bond strength values than subgroup II in all tested groups. The difference between each subgroup in groups A, B, and C was significant.

Conclusions: 1. Diabetes mellitus has an adverse effect on the shear bond strength of composite to dentine. 2. Type 1 diabetes mellitus significantly reduces the shear bond strength of composite resin to dentin. 3. Shear bond strength of the universal adhesive was higher when applied to dentin using the self-etch mode, as compared to the total etch mode, in all groups, regardless of whether the participants had diabetes or not. Key words:Diabetes Mellitus, Universal Adhesive, Application Mode, Shear bond Strength, Dentine, Composite.