The Morphology of Peri-Implantitis Bone Defects: A Retrospective Study on Periapical Radiographs

Int J Dent. 2024 Apr 30:2024:4324114. doi: 10.1155/2024/4324114. eCollection 2024.

Abstract

Objectives: The aims of this study were to assess the morphologic features of peri-implant defects, as measured on 2D intraoral radiographs, and to investigate the possible correlation between such morphology and other parameters related to the position and characteristics of the implant or the implant-supported prosthesis.

Materials and methods: Implants with peri-implantitis were included in this retrospective study. Data collected were related both to the patients and to the position/characteristics of the implants and the implant-supported prosthesis. Measurements of the morphologic defects were performed by two operators on digitalized intraoral periapical radiographs. Results and Conclusion. In total, 73 implants in 27 patients were included. The measurements of the periapical radiograph suggested that the most common defect conformation was crateriform, with both intraosseous and horizontal components. An inverse correlation was found between the extension of the peri-implant lesion and the time between the radiographic assessment and the implant placement. The total lesion area was strongly correlated to oral hygiene levels. No correlations between lesion extension and smoking, diabetes, history of periodontal were found. In conclusion, the results from this 2D radiographic study showed the prevalence of crateriform peri-implant defects, with a hygiene-correlated extension, perceptible on the mesial and distal aspects; 3D imaging could be used when available for further research and clinical investigation.