Dedicated locking plate reduces non-union risk in open ankle fusion in obese patients

Orthop Traumatol Surg Res. 2024 May 3:103901. doi: 10.1016/j.otsr.2024.103901. Online ahead of print.

Abstract

Introduction: Obesity is a growing public health concern. In ankle osteoarthritis, non-conservative treatment in advanced stages consists in ankle fusion, or else total ankle replacement, for which obesity is a relative contraindication. One of main complications of ankle fusion is non-union. Devascularization, obesity and fixation material are all factors involved in postoperative non-union, and have to be taken into account in surgical strategy for reliable results. The objective of this study was to compare the rate of ankle non-union in obese patients using quadruple screwing or a dedicated locking plate. The hypothesis was that the locking plate limits the risk of non-union in this population.

Methods: All patients were obese (BMI>30kg/m2) and presented ankle osteoarthritis with>10° intra-articular deformity. The approach and joint preparation were performed via an anteromedial approach. Group S was composed of 32 patients, operated on by quadruple screwing; group P comprised 10 patients operated on using a dedicated locking plate. The main endpoint was a significant difference in the rate of non-union between the 2 groups. The secondary endpoint was improvement in pre- and 6-month postoperative AOFAS score.

Results: Group S presented 31% non-union (10/32) and group P 0% (0/10) (p<0.05). Postoperative AOFAS score was significantly higher in group P: 67.8±10.4 [range, 40-92] vs. 83.1±8.0 [range, 64-92] (p<0.05).

Conclusion: The dedicated anterior locking plate is a technique of choice for ankle fusion in obese patients with intra-articular deformity>10°, to limit the risk of non-union.

Level of evidence: IV; retrospective study.

Keywords: Ankle fusion; Ankle osteoarthritis; Dedicated locking plate; Non-union; Obesity.