The role of electrodiagnosis in focal neuropathies

Handb Clin Neurol. 2024:201:43-59. doi: 10.1016/B978-0-323-90108-6.00010-7.

Abstract

Electrodiagnostic (EDX) testing plays an important role in confirming a mononeuropathy, localizing the site of nerve injury, defining the pathophysiology, and assessing the severity and prognosis. The combination of nerve conduction studies (NCS) and needle electromyography findings provides the necessary information to fully assess a nerve. The pattern of NCS abnormalities reflects the underlying pathophysiology, with focal slowing or conduction block in neuropraxic injuries and reduced amplitudes in axonotmetic injuries. Needle electromyography findings, including spontaneous activity and voluntary motor unit potential changes, complement the NCS findings and further characterize chronicity and degree of axon loss and reinnervation. EDX is used as an objective marker to follow the progression of a mononeuropathy over time.

Keywords: Axon loss; Conduction block; Demyelination; Mononeuropathy; Needle electromyography; Nerve conduction studies.

Publication types

  • Review

MeSH terms

  • Electrodiagnosis* / methods
  • Electromyography / methods
  • Humans
  • Neural Conduction* / physiology
  • Peripheral Nervous System Diseases / diagnosis
  • Peripheral Nervous System Diseases / physiopathology