Association of Renin-Angiotensin-Aldosterone System Inhibitors With Clinical Outcomes, Hemodynamics, and Myocardial Remodeling Among Patients With Advanced Heart Failure on Left Ventricular Assist Device Support

J Am Heart Assoc. 2024 May 7;13(9):e032617. doi: 10.1161/JAHA.123.032617. Epub 2024 Apr 30.

Abstract

Background: We evaluated the potential benefits of renin-angiotensin-aldosterone system inhibitors (RAASi) in patients with left ventricular assist device support.

Methods and results: A total of 165 consecutive patients undergoing left ventricular assist device implant and alive at 6-month on support were studied. RAASi status after 6-month visit along with clinical reasons for nonprescription/uptitration were retrospectively assessed. The primary outcome was a composite of heart failure hospitalization or cardiovascular death between 6 and 24 months after left ventricular assist device implant. Remodeling and hemodynamic outcomes were explored by studying the association of RAASi new prescription/uptitration versus unmodified therapy at 6-month visit with the change in echocardiographic parameters and hemodynamics between 6 and 18 months. After the 6-month visit, 76% of patients were on RAASi. Patients' characteristics among those receiving and not receiving RAASi were mostly similar. Of 85 (52%) patients without RAASi new prescription/uptitration at 6-month visit, 62% had no apparent clinical reason. RAASi were independently associated with the primary outcome (adjusted hazard ratio, 0.31 [95% CI, 0.16-0.69]). The baseline rates of optimal echocardiographic profile (neutral interventricular septum, mitral regurgitation less than mild, and aortic valve opening) and hemodynamic profile (cardiac index ≥2.2 L/min per m2, wedge pressure <18 mm Hg, and right atrial pressure <12 mm Hg) were similar between groups. At 18 months, patients receiving RAASi new prescription/uptitration at 6 months had higher rates of optimal hemodynamic profile (57.5% versus 37.0%; P=0.032) and trends for higher rates of optimal echocardiographic profile (39.6% versus 22.9%; P=0.055) compared with patients with 6-month unmodified therapy. Optimal 18-month hemodynamic and echocardiographic profiles were associated with the primary outcome (log-rank=0.022 and log-rank=0.035, respectively).

Conclusions: RAASi are associated with improved outcomes and improved hemodynamics among mechanically unloaded patients.

Keywords: advanced heart failure; hemodynamics; left ventricular assist device; medical therapy; renin‐angiotensin‐aldosterone system inhibitors.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Angiotensin Receptor Antagonists / therapeutic use
  • Angiotensin-Converting Enzyme Inhibitors / therapeutic use
  • Echocardiography
  • Female
  • Heart Failure* / drug therapy
  • Heart Failure* / mortality
  • Heart Failure* / physiopathology
  • Heart Failure* / therapy
  • Heart-Assist Devices*
  • Hemodynamics* / drug effects
  • Humans
  • Male
  • Middle Aged
  • Renin-Angiotensin System* / drug effects
  • Retrospective Studies
  • Time Factors
  • Treatment Outcome
  • Ventricular Function, Left / drug effects
  • Ventricular Remodeling* / drug effects

Substances

  • Angiotensin-Converting Enzyme Inhibitors
  • Angiotensin Receptor Antagonists