Transfemoral leadless pacemaker implantation after interventional or surgical tricuspid valve repair

Europace. 2024 May 2;26(5):euae111. doi: 10.1093/europace/euae111.

Abstract

Implantation in a patient with transcatheter tricuspid valve annuloplasty (A), transcatheter valve replacement (B, C), and a combination of transcatheter annuloplasty and edge-to-edge repair (D). LAO, left anterior oblique; PM, pacemaker; RAO, right anterior oblique; TR, tricuspid regurgitation.

Keywords: Alternative pacing modality; Leadless pacemaker; Tricuspid valve disease; Tricuspid valve repair; Tricuspid valve replacement.

Publication types

  • Case Reports

MeSH terms

  • Aged
  • Aged, 80 and over
  • Cardiac Pacing, Artificial / methods
  • Female
  • Femoral Artery / surgery
  • Heart Valve Prosthesis Implantation / methods
  • Humans
  • Male
  • Pacemaker, Artificial*
  • Treatment Outcome
  • Tricuspid Valve Insufficiency / surgery
  • Tricuspid Valve* / diagnostic imaging
  • Tricuspid Valve* / surgery