Membrane-Free Lateral Flow Assay with the Active Control of Fluid Transport for Ultrasensitive Cardiac Biomarker Detection

Anal Chem. 2024 May 7;96(18):7014-7021. doi: 10.1021/acs.analchem.4c00142. Epub 2024 Apr 24.

Abstract

Membrane-based lateral flow immunoassays (LFAs) have been employed as early point-of-care (POC) testing tools in clinical settings. However, the varying membrane properties, uncontrollable sample transport in LFAs, visual readout, and required large sample volumes have been major limiting factors in realizing needed sensitivity and desirable precise quantification. Addressing these challenges, we designed a membrane-free system in which the desirable three-dimensional (3D) structure of the detection zone is imitated and used a small pump for fluid flow and fluorescence as readout, all the while maintaining a one-step assay protocol. A hydrogel-like protein-polyelectrolyte complex (PPC) within a polyelectrolyte multilayer (PEM) was developed as the test line by complexing polystreptavidin (pSA) with poly(diallyldimethylammonium chloride) (PDDA), which in turn was layered with poly(acrylic acid) (PAA) resulting in a superior 3D streptavidin-rich test line. Since the remainder of the microchannel remains material-free, good flow control is achieved, and with the total volume of 20 μL, 7.5-fold smaller sample volumes can be used in comparison to conventional LFAs. High sensitivity with desirable reproducibility and a 20 min total assay time were achieved for the detection of NT-proBNP in plasma with a dynamic range of 60-9000 pg·mL-1 and a limit of detection of 56 pg·mL-1 using probe antibody-modified fluorescence nanoparticles. While instrument-free visual detection is no longer possible, the developed lateral flow channel platform has the potential to dramatically expand the LFA applicability, as it overcomes the limitations of membrane-based immunoassays, ultimately improving the accuracy and reducing the sample volume so that finger-prick analyses can easily be done in a one-step assay for analytes present at very low concentrations.

Publication types

  • Research Support, Non-U.S. Gov't
  • Research Support, N.I.H., Extramural

MeSH terms

  • Acrylic Resins / chemistry
  • Biomarkers* / analysis
  • Biomarkers* / blood
  • Humans
  • Immunoassay / methods
  • Limit of Detection
  • Natriuretic Peptide, Brain / analysis
  • Natriuretic Peptide, Brain / blood
  • Peptide Fragments / analysis
  • Peptide Fragments / blood
  • Polyethylenes / chemistry
  • Polystyrenes / chemistry
  • Quaternary Ammonium Compounds*

Substances

  • Biomarkers
  • Natriuretic Peptide, Brain
  • Acrylic Resins
  • carbopol 940
  • Peptide Fragments
  • pro-brain natriuretic peptide (1-76)
  • poly-N,N-dimethyl-N,N-diallylammonium chloride
  • Polyethylenes
  • Polystyrenes
  • Quaternary Ammonium Compounds