Thin-slice elbow MRI with deep learning reconstruction: Superior diagnostic performance of elbow ligament pathologies

Eur J Radiol. 2024 Apr 16:175:111471. doi: 10.1016/j.ejrad.2024.111471. Online ahead of print.

Abstract

Purpose: With the slice thickness routinely used in elbow MRI, small or subtle lesions may be overlooked or misinterpreted as insignificant. To compare 1 mm slice thickness MRI (1 mm MRI) with deep learning reconstruction (DLR) to 3 mm slice thickness MRI (3 mm MRI) without/with DLR, and 1 mm MRI without DLR regarding image quality and diagnostic performance for elbow tendons and ligaments.

Methods: This retrospective study included 53 patients between February 2021 and January 2022, who underwent 3 T elbow MRI, including T2-weighted fat-saturated coronal 3 mm and 1 mm MRI without/with DLR. Two radiologists independently assessed four MRI scans for image quality and artefacts, and identified the pathologies of the five elbow tendons and ligaments. In 19 patients underwent elbow surgery after elbow MRI, diagnostic performance was evaluated using surgical records as a reference standard.

Results: For both readers, 3 mm MRI with DLR had significant higher image quality scores than 3 mm MRI without DLR and 1 mm MRI with DLR (all P < 0.01). For common extensor tendon and elbow ligament pathologies, 1 mm MRI with DLR showed the highest number of pathologies for both readers. The 1 mm MRI with DLR had the highest kappa values for all tendons and ligaments. For reader 1, 1 mm MRI with DLR showed superior diagnostic performance than 3 mm MRI without/with DLR. For reader 2, 1 mm MRI with DLR showed the highest diagnostic performance; however, there was no significant difference.

Conclusions: One mm MRI with DLR showed the highest diagnostic performance for evaluating elbow tendon and ligament pathologies, with similar subjective image qualities and artefacts.

Keywords: Deep learning; Elbow; Ligaments; Magnetic resonance imaging; Tendons.