Does Tri-Staple™ technology reduce the risk of anastomotic leakage in colorectal surgery? A propensity score matching analysis

J Surg Oncol. 2024 Apr 17. doi: 10.1002/jso.27650. Online ahead of print.

Abstract

Background and objectives: This study evaluates the Tri-Staple™ technology in colorectal anastomosis.

Methods: Patients who underwent rectosigmoidectomy between 2016 and 2022 were retrospectively evaluated and divided into two groups: EEA™ (EEA) or Tri-Staple™ (Tri-EEA). The groups were matched for age, sex, American Society of Anesthesiologists (ASA), and neoadjuvant radiotherapy using propensity score matching (PSM).

Result: Three hundred and thirty-six patients were included (228 EEA; 108 Tri-EEA). The groups were similar in sex, age, and neoadjuvant therapy. The Tri-EEA group had fewer patients with ASA III/IV scores (7% vs. 33%; p < 0.001). The Tri-EEA group had a lower incidence of leakage (4% vs. 11%; p = 0.023), reoperations (4% vs. 12%; p = 0.016), and severe complications (6% vs. 14%; p = 0.026). There was no difference in complications, mortality, readmission, and length of stay. After PSM, 108 patients in the EEA group were compared with 108 in the Tri-EEA group. The covariates sex, age, neoadjuvant radiotherapy, and ASA were balanced, and the risk of leakage (4% vs. 12%; p = 0.04), reoperation (4% vs. 14%; p = 0.014), and severe complications (6% vs. 15%; p = 0.041) remained lower in the Tri-EEA group.

Conclusion: Tri-Staple™ reduces the risk of leakage in colorectal anastomosis. However, this study provides only insights, and further research is warranted to confirm these findings.

Keywords: anastomotic leak; colorectal surgery; rectal neoplasms.