Towards standardisation of surface electromyography measurements in the horse: Bipolar electrode location

J Electromyogr Kinesiol. 2024 Jun:76:102884. doi: 10.1016/j.jelekin.2024.102884. Epub 2024 Apr 1.

Abstract

The use of surface electromyography in the field of animal locomotion has increased considerably over the past decade. However, no consensus exists on the methodology for data collection in horses. This study aimed to start the development of recommendations for bipolar electrode locations to collect surface electromyographic data from horses during dynamic tasks. Data were collected from 21 superficial muscles of three horses during trot on a treadmill using linear electrode arrays. The data were assessed both quantitatively (signal-to-noise ratio (SNR) and coefficient of variation (CoV)) and qualitatively (presence of crosstalk and activation patterns) to compare and select electrode locations for each muscle. For most muscles and horses, the highest SNR values were detected near or cranial/proximal to the central region of the muscle. Concerning the CoV, there were larger differences between muscles and horses than within muscles. Qualitatively, crosstalk was suspected to be present in the signals of twelve muscles but not in all locations in the arrays. With this study, a first attempt is made to develop recommendations for bipolar electrode locations for muscle activity measurements during dynamic contractions in horses. The results may help to improve the reliability and reproducibility of study results in equine biomechanics.

Keywords: Electrode array; Equine; Gait; Methodology; sEMG.

MeSH terms

  • Animals
  • Electrodes*
  • Electromyography* / methods
  • Electromyography* / standards
  • Horses / physiology
  • Muscle Contraction / physiology
  • Muscle, Skeletal* / physiology
  • Reproducibility of Results
  • Signal-To-Noise Ratio*