Sutures, Screws, Buttons, and Anchors: A Review of Current Bone Graft Fixation Devices for Glenoid Bone Loss in the Unstable Shoulder

Curr Rev Musculoskelet Med. 2024 Jun;17(6):207-221. doi: 10.1007/s12178-024-09895-x. Epub 2024 Apr 8.

Abstract

Purpose of review: Anterior shoulder instability is associated with concomitant injury to several stabilizing structures of the shoulder, including glenoid bone loss. While instability is most common in young athletes and patients with predisposing conditions of hyperlaxity, recurrent shoulder instability can occur throughout various age ranges and may lead to longer term effects including pain and shoulder arthritis. Glenoid bone loss exceeding certain thresholds is generally treated by glenoid reconstruction via bone block augmentation to adequately stabilize the glenohumeral joint. These procedures increase the width of the articular surface on which the humeral head can translate before dislocation and, based on the procedure performed, provide a sling effect via the conjoined tendon, and increase tension to support the anterior capsule. The purpose of this review is to summarize the available literature regarding bone block fixation techniques.

Recent developments: Various fixation techniques have been utilized to secure bone block transfers. Though screw fixation has traditionally been used for bone block fixation, suture buttons, suture anchors, and all-suture techniques have been utilized in attempts to avoid complications associated with the use of screws. Biomechanical studies report variable force-resistance, displacement, and mode of failure when comparing screw to suture button-based fixation of glenoid bone blocks. Clinical and radiographic studies have shown these novel suture-based techniques to be comparable, and in some cases advantageous, to traditional screw fixation techniques. While screw fixation has long been the standard of care in glenoid bone block procedures, it is associated with high complication rates, leading surgeons to endeavor toward new fixation techniques. In available biomechanical studies, screw fixation has consistently demonstrated high maximal load-to-failure and displacement with cyclic loading. Studies have reported similar clinical and radiographic outcomes in both screw and suture-based fixation methods, with evidence of reduced bone resorption with suture fixation. While suture button fixation is associated with a higher rate of recurrent instability, overall complication rates are low. Future research should address biomechanical shortcomings of suture-based fixation techniques and continue to assess long-term follow-up of patients treated with each fixation method.

Keywords: Glenoid bone block fixation biomechanics; Glenoid cerclage; Glenoid suture anchor; Glenoid suture button; Latarjet fixation; Shoulder instability.

Publication types

  • Review