Systematic evaluation of machine learning-enhanced trifocal IOL power selection for axial myopia cataract patients

Comput Biol Med. 2024 May:173:108245. doi: 10.1016/j.compbiomed.2024.108245. Epub 2024 Mar 14.

Abstract

Purpose: This study aimed to evaluate and optimize intraocular lens (IOL) power selection for cataract patients with high axial myopia receiving trifocal IOLs.

Design: A multi-center, retrospective observational case series was conducted. Patients having an axial length ≥26 mm and undergoing cataract surgery with trifocal IOL implanted were studied.

Methods: Preoperative biometric and postoperative outcome data from 139 eyes were collected to train and test various machine learning (ML) models (support vector machine, linear regression, and stacking regressor) using five-fold cross-validation. The models' performance was further validated externally using data from 48 eyes enrolled from other hospitals. Performance of seven IOL calculation formulas (BUII, Kane, EVO, K6, DGS, Holladay I, and SRK/T) were examined with and without ML models.

Results: The results of cross-validation revealed improvements across all IOL calculation formulas, especially for K6 and Holladay I. The model increased the percentage of eyes with a prediction error (PE) within ±0.50 D from 71.94% to 79.14% for K6, and from 35.25% to 51.80% for Holladay I. In external validation involving 48 patients from other centers, six out of seven formulas demonstrated a reduction in the mean absolute error (MAE). K6's PE within ±0.50 D improved from 62.50% to 77.08%, and Holladay I from 16.67% to 58.33%.

Conclusions: In this study, we conducted a comprehensive evaluation of seven IOL power calculation formulas in high axial myopia cases and explored the effectiveness of the Stacking Regressor model in augmenting their accuracy. Of these formulas, K6 and Holladay I exhibited the most significant improvements, suggesting that integrating ML may have varying levels of effectiveness across different formulas but holds substantial promise in improving the predictability of IOL power calculations in patients with long eyes.

Keywords: Axial myopia; Cataract; IOL formula; Machine learning; Trifocal IOL.

Publication types

  • Case Reports
  • Multicenter Study
  • Observational Study

MeSH terms

  • Cataract*
  • Humans
  • Lenses, Intraocular*
  • Myopia* / surgery
  • Optics and Photonics
  • Refraction, Ocular
  • Retrospective Studies