Hydraulic containment of TCE contaminated groundwater using pulsed pump-and-treat: Performance evaluation and vapor intrusion risk assessment

Environ Pollut. 2024 Apr 15:347:123683. doi: 10.1016/j.envpol.2024.123683. Epub 2024 Feb 28.

Abstract

Remedial actions for groundwater contamination such as containment, in-situ remediation, and pump-and-treat have been developed. This study investigates the hydraulic containment of Trichloroethylene (TCE) contaminated groundwater by using pulsed pump-and-treat technology. The hypothetical research site assumed the operation of pulsed pump-and-treat to manage groundwater contaminated with 0.1 mg/L of TCE. at the pump-and-treat facility. Numerical models, employing MODFLOW and MT3DMS for groundwater flow and contamination simulations, were used for case studies to evaluate the performance and risks of pump-and-treat operation strategies. Evaluation criteria included capture width, removal efficiency, and contaminant leakage. Health risks from TCE leakage were assessed using a vapor intrusion risk assessment tool in adjacent areas. In the facility-scale case study, the capture width of the pump-and-treat was controlled by pumping/injection well operations, including schedules and rates. Pumping/injection well configurations impacted facility efficiencies. Pulsed operation led to TCE leakage downstream. Site-scale case studies simulated contaminant transport through pump-and-treat considering various operation stages (continuous; pulsed), as well as various reactions of TCE in subsurface environment (non-reactive; sorption; sorption and biodegradation). Assuming non-reactive tracer, TCE in groundwater was effectively blocked during continuous operation stage but released downstream in the following pulsed operation stage. Considering chemical reactions, the influences of the pump-and-treat operation followed similar trends of the non-reactive tracer but occurred at delayed times. Groundwater contamination levels were reduced through biodegradation. Cancer and non-cancer risks could occur at points of exposure (POEs) where the contamination levels approached or fell below TCE groundwater standards.

Keywords: Groundwater contamination; Leakage; Numerical simulation; Pulsed pump-and-treat; TCE; Vapor intrusion risk.

MeSH terms

  • Biodegradation, Environmental
  • Gases
  • Groundwater*
  • Trichloroethylene* / metabolism
  • Water Pollutants, Chemical* / analysis

Substances

  • Trichloroethylene
  • Water Pollutants, Chemical
  • Gases