Development and validation of the ASGARD risk score for safe monitoring in asymptomatic nonsevere aortic stenosis

Eur J Prev Cardiol. 2024 Feb 28:zwae086. doi: 10.1093/eurjpc/zwae086. Online ahead of print.

Abstract

Aims: Current guidelines recommend serial echocardiography at minimum 1-2 year intervals for monitoring patients with nonsevere aortic valve stenosis (AS), which is costly and often clinically inconsequential.We aimed to develop and test whether the biomarker-based ASGARD risk score (Aortic Valve Stenosis Guarded by Amplified Risk Determination) can guide the timing of echocardiograms in asymptomatic patients with nonsevere AS.

Methods: The development cohort comprised 1,093 of 1,589 (69%) asymptomatic patients with mild-to-moderate AS who remained event-free one year after inclusion into the SEAS trial. Cox regression landmark analyses with a 2-year follow-up identified the model (ASGARD) with the lowest Akaike information criterion for association to AS-related composite outcome (heart failure hospitalization, aortic valve replacement, or cardiovascular death). Fine-Gray analyses provided cumulative event rates by ASGARD score quartiles. The ASGARD score was internally validated in the remaining 496 patients (31%) from the SEAS-cohort and externally in 71 asymptomatic outpatients with nonsevere AS from six Copenhagen hospitals.

Results: The ASGARD score comprises updated measurements of heart rate and age- and sex-adjusted N-terminal pro-brain natriuretic peptide upon transaortic maximal velocity (Vmax) from the previous year. The ASGARD score had high predictive accuracy across all cohorts (external validation: area under the curve: 0.74 [95% CI, 0.62-0.86]), and similar to an updated Vmax measurement. An ASGARD score ≤50% was associated with AS-related event rates ≤5% for a minimum of 15 months.

Conclusion: The ASGARD score could provide a personalized and safe surveillance alternative to routinely planned echocardiograms, so physicians can prioritize echocardiograms for high-risk patients.

Keywords: NT-proBNP; aortic valve stenosis; biomarkers; echocardiography; heart rate; risk prediction model; surveillance.

Plain language summary

In this study, we developed and examined the potential of the novel ASGARD risk score to tailor personalized follow-up intervals for diagnostic heart scans, incorporating updated heart rate and blood marker measurements along with the heart scan data from the previous year. Patients with the ASGARD risk score within the lowest 50% had a low annual risk of aortic valve-related events (less than 5%) for a minimum of 15 months.In clinical settings, the ASGARD score could provide a personalized and safe monitoring alternative to routine heart scans, prioritizing the diagnostic heart scans for high-risk patients.