Clinical outcomes of the robot-assisted Ivor Lewis procedure for adenocarcinoma of the esophagogastric junction with semi-instrument overlap intrathoracic anastomosis

J Thorac Dis. 2024 Jan 30;16(1):542-552. doi: 10.21037/jtd-23-1856. Epub 2024 Jan 16.

Abstract

Background: The main difficulty of minimally invasive Ivor Lewis (IL) procedure for adenocarcinoma of the esophagogastric junction (AEGJ) is the intrathoracic esophagogastric anastomosis (IEA). We aimed to assess the safety and feasibility of the IL procedure with the da Vinci surgical system for treatment of AEGJ with semi-mechanical intrathoracic IEA.

Methods: The cohort included 72 patients with AEGJ who received treatment at the Department of Minimally Invasive Esophagus Surgery of the Tianjin Medical University Cancer Institute and Hospital from August 2020 to March 2023. Of these 72 patients, 17 received neoadjuvant chemo-immunotherapy. The robot-assisted minimally invasive IL procedure was performed using a linear stapler for overlap side-to-side intrathoracic anastomosis and the stapler defect was closed with double full-layer continuous sutures by robotic hand-sewn (semi-mechanical) IEA.

Results: Of the 72 AEGJ patients, 2 were converted to exploration, 7 were converted to laparotomy and thoracotomy for circular-stapled intrathoracic anastomosis, and 6 were converted to thoracotomy for circular-stapled anastomosis, which included 2 cases of extensive pleural adhesion and 4 cases of overlap anastomosis failure, whereas 57 underwent the robot-assisted minimally invasive IL procedure with semi-mechanical IEA. Among the 9 patients converted to laparotomy, the laparotomy rate was closely related to the Siewert classification (P<0.005) and preoperative use of neoadjuvant therapy (P<0.05). Among the 57 patients who underwent the robot-assisted minimally invasive IL procedure with semi-mechanical IEA, there were 2 cases of anastomotic leakages (2/57, 3.5%), no case of anastomotic stricture, 5 cases of postoperative pneumonia (5/57, 8.77%), 2 cases of intensive care unit admission (2/57, 3.5%), and 1 case of readmission within 30 days (1/57, 1.75%). None of the patients died within 30 days after surgery.

Conclusions: The robot-assisted minimally invasive IL procedure with semi-mechanical IEA is both safe and feasible for AEGJ. However, caution is advised for patients with Siewert type III AEGJ and those who have already received preoperative neoadjuvant therapy.

Keywords: Adenocarcinoma of the esophagogastric junction (AEGJ); Ivor Lewis procedure (IL procedure); anastomotic leakage; da Vinci surgical system.