Disinfection of Bacteria in Aerosols by Applying High Voltage to Stranded Wire Electrodes

Microorganisms. 2024 Feb 19;12(2):418. doi: 10.3390/microorganisms12020418.

Abstract

The inactivation of airborne pathogenic microorganisms is crucial to attenuate the dissemination of infectious diseases induced by airborne pathogens. Conventional air disinfection methodologies, such as ultraviolet (UV) irradiation and ozone treatment, have demonstrated limited efficacy. Consequently, we investigated the potential of employing pulsed voltages to effectively eradicate bacteria within aerosols. Our inquiry revealed that the bacterial disinfection rate increased proportionally with elevated applied voltage and frequency. For instance, when a pulsed voltage of 20 kV and a frequency of 500 Hz were applied, a substantial disinfection rate exceeding 6.0 logarithmic units was attained. Furthermore, with the utilization of the stranded wire anodes, the disinfection intensity could be augmented by up to 2.0 logarithmic units compared with the solid wire configuration. Through the utilization of a stranded wire electrode model, we scrutinized the electric field encompassing the electrode, revealing a non-uniform electric field with the stranded wire electrode. This observation indicated an amplified bacterial disinfection effect, aligning with our experimental outcomes. These findings significantly enhance our comprehension of efficacious approaches to electrically disinfecting airborne bacteria.

Keywords: disinfection of bacteria in aerosol; impulse voltage; pulsed electric field (PEF); stranded wire electrode.