Appropriate Endotracheal Tube Position for Percutaneous Dilatational Tracheostomy: A Single-Center Observational Study

Cureus. 2024 Jan 8;16(1):e51895. doi: 10.7759/cureus.51895. eCollection 2024 Jan.

Abstract

Aim This study aimed to investigate the appropriate endotracheal tube (ETT) position during percutaneous dilatational tracheostomy (PDT). Methods This single-center observational study included hospitalized patients who underwent surgical tracheostomy (ST) between August 2021 and October 2022. During ST, the trachea was opened, and the ETT was pulled out visually. It stopped when the ETT was no longer visible, and the tracheostomy tube was placed in the trachea. The ETT position was measured by considering the ETT position during ST to be the appropriate position during PDT. The correlation between the measured ETT position and patient characteristics was evaluated. A prediction equation for the ETT position was derived from the derivation group, and validation of the prediction equation was evaluated by the validation group. Results Forty-six and 15 patients were in the derivation and validation groups, respectively. Weight, duration of intubation, and in-hospital mortality were significantly different between the two groups. The measured ETT position correlated with body height (r=0.60, p<0.001) and sex (r=0.45, p=0.002), while the ETT position before ST showed a weak correlation (r=0.34, p=0.020). The predicted and measured values in the validation group correlated with each other (r=0.58, p=0.024). Conclusion The appropriate ETT position for PDT correlates with body height, and the equation "body height×0.112-0.323 cm" was derived. This predictive equation may be useful as a guide for ETT positioning during PDT puncture.

Keywords: endotracheal tube; endotracheal tube position; percutaneous dilatational tracheostomy; prediction equation; surgical tracheostomy.