Computed tomography-guided microwave ablation for right middle lobe pulmonary nodules: a retrospective, single-center, case-control study

Int J Hyperthermia. 2024;41(1):2307479. doi: 10.1080/02656736.2024.2307479. Epub 2024 Feb 5.

Abstract

Purpose: This retrospective, single-center, case-control study evaluated the safety and efficacy of Computed tomography (CT)-guided microwave ablation (MWA) for pulmonary nodules located in the right middle lobe (RML), a challenging location associated with a high frequency of complications.

Methods: Between May 2020 and April 2022, 71 patients with 71 RML pulmonary nodules underwent 71 MWA sessions. To comparison, 142 patients with 142 pulmonary nodules in non-RML were selected using propensity score matching. The technical success, technique efficacy, complications, and associated factors were analyzed. The duration of the procedure and post-ablation hospital stay were also recorded.

Results: Technical success was achieved in 100% of all patients. There were no significant differences in technique efficacy rates between the RML and non-RML groups (97.2% vs. 95.1%, p = 0.721). However, both major (47.9% vs. 19.7%, p < 0.001) and minor (26.8% vs. 11.3%, p = 0.004) pneumothorax were more common in the RML group than non-RML group. MWA for RML pulmonary nodules was identified as an independent risk factor for pneumothorax (p < 0.001). The duration of procedures (51.7 min vs. 35.3 min, p < 0.001) and post-ablation hospital stays (4.7 days vs. 2.8 days, p < 0.001) were longer in the RML group than non-RML group.

Conclusions: CT-guided MWA for RML pulmonary nodules showed comparable efficacy compared with other lobes, but posed a higher risk of pneumothorax complications, necessitating longer MWA procedure times and extended hospital stays.

Keywords: Right middle lobe; complication; microwave ablation; pneumothorax; pulmonary nodule.

MeSH terms

  • Case-Control Studies
  • Catheter Ablation* / methods
  • Humans
  • Microwaves / therapeutic use
  • Pneumothorax* / etiology
  • Retrospective Studies
  • Tomography
  • Tomography, X-Ray Computed / methods