Synergistic effect of UV-A and UV-C light is traced to UV-induced damage of the transfer RNA

Water Res. 2024 Mar 15:252:121189. doi: 10.1016/j.watres.2024.121189. Epub 2024 Jan 24.

Abstract

UV light emitting diodes (LEDs) are considered the new frontier of UV water disinfection. As UV technologies continue to evolve, so does the need to understand disinfection mechanisms to ensure that UV treatment continues to adequately protect public health. In this research, two Escherichia coli (E. coli) strains (the wild type K12 MG1655 and K12 SP11 (ThiI E342K)) were irradiated with UV-C at 268 nm both independently and after exposure to UV-A (365 nm). A synergistic effect was found on the viability of the wild type E. coli K12 strain when UV-A irradiation was applied prior to UV-C. Sublethal UV-A doses, which had a negligible effect on cell viability alone, enhanced UV-C inactivation by several orders of magnitude. This indicated a specific cellular response mechanism to UV-A irradiation, which was traced to direct photolysis of the transfer RNA (tRNA), which are critical links in the translation of messenger RNA to proteins. The wild type K12 strain MG1655, containing tRNAs with a thiolated uridine, directly absorbs the UV-A light, which leads to a reduction in protein synthesis, making them more susceptible to UV-C induced damage. However, the K12 strain SP11 (ThiI E342K), with a point mutation in the thiI gene that prevents a post-transcriptional modification of tRNA, experienced less inactivation upon subsequent irradiation by UV-C. The growth rate of cells, which was inhibited by sublethal UV-A doses, was not inhibited in this mutant strain with the modified tRNA. Time-lapse microscopy with microfluidics showed that sub-lethal UV-A caused a transient, reversible, growth arrest in E. coli. However, once the growth resumed, the cell division time resembled that of unirradiated cells. Damage induced by UV-A impaired the recovery of damage induced by UV-C. Depending on the UV-A dose applied, the synergistic effect remained even when there was a time delay of several hours between UV-A and UV-C exposures. The effect of sublethal UV-A was reversible over time; therefore, the synergistic effect was strongest when UV-C was applied immediately after UV-A. Combining UV-A and UV-C irradiation may serve as a practical tool to increase UV disinfection efficacy, which could potentially reduce costs while still adequately protecting public health.

Keywords: Combined wavelengths; E. coli; Synergistic effect; UV LEDs; UV inactivation mechanisms; tRNA.

MeSH terms

  • Disinfection
  • Escherichia coli* / genetics
  • Escherichia coli* / radiation effects
  • RNA, Transfer
  • Ultraviolet Rays
  • Water Purification*

Substances

  • RNA, Transfer