A comparative study on efficacy of immediate and delayed placement of cylindrical and tapered dental implants: A clinical prospective study

Natl J Maxillofac Surg. 2023 Sep-Dec;14(3):433-437. doi: 10.4103/njms.njms_65_22. Epub 2023 Nov 10.

Abstract

Introduction: The study deals with improving the understanding of implant design in various situations.

Materials and method: 40 implants were placed out of which 20 were tapered and rest were cylindrical. These were further divided into immediate and delayed settings. The patients were followed upto 6 months and the results were compiled.

Result: Statistically significant difference were found between tapered and cylindrical implants in terms of quality of osseointegration and maintenance of crestal bone height.

Conclusion: It has been gathered from the study that while delayed placement suggests waiting time period varying between 3 and 6 months, it offers a predictable procedure in terms of visibility, good implant-bone contact, and closure all of which, promote a better outcome for dental implant therapy. Immediate implant placement solution is very viable in reducing the time period involved in dental implant therapy. Apart from few to minimum contraindications, it can be predictably performed.

Keywords: Cylindrical implants; delayed placement; immediate placement; osseointegration; tapered implants.