Impact of socioeconomic status on chronic control and complications of type 1 diabetes mellitus in users of glucose flash systems: a follow-up study

BMC Med. 2024 Jan 25;22(1):37. doi: 10.1186/s12916-024-03254-w.

Abstract

Background: This study investigates the association between socioeconomic status (SES) and glycemic control in individuals with type 1 diabetes (T1D) using flash glucose monitoring (FGM) devices within a public health system where these technologies are freely available and utilized according to recommended guidelines.

Methods: A follow-up study of 1060 adults (mean age 47.4 ± 15.0 years, 49.0% women) with T1D, receiving care at three Spanish university hospitals that regularly employ the FGM system. SES was assessed using the Spanish Deprivation Index and the average annual net income per person. Glycemic data were collected over a 14-day follow-up period, including baseline glycated hemoglobin (HbA1c) levels prior to sensor placement, the last available HbA1c levels, and FGM-derived glucose metrics. Individuals with sensor usage time < 70% were excluded. Chronic micro and macrovascular complications related to diabetes were documented. Regression models, adjusted for clinical variables, were employed to determine the impact of SES on optimal sensor control (defined as time in range (TIR) ≥ 70% with time below range < 4%) and disease complications.

Results: The average follow-up was of 2 years. The mean TIR and the percentage of individuals with optimal control were higher in individuals in the highest SES quartile (64.9% ± 17.8% and 27.9%, respectively) compared to those in the lowest SES quartile (57.8 ± 17.4% and 12.1%) (p < 0.001). Regression models showed a higher risk of suboptimal control (OR 2.27, p < 0.001) and ischemic heart disease and/or stroke (OR 3.59, p = 0.005) in the lowest SES quartile. No association was observed between SES and the risk of diabetic nephropathy and retinopathy. FGM system improved HbA1c levels across all SES quartiles. Although individuals in the highest SES quartile still achieved a significantly lower value at the end of the follow-up 55 mmol/mol (7.2%) compared to those in the lowest SES quartile 60 mmol/mol (7.6%) (p < 0.001), the significant disparities in this parameter between the various SES groups were significantly reduced after FGM technology use.

Conclusions: Socioeconomic status plays a significant role in glycemic control and complications in individuals with T1D, extending beyond access to technology and its proper utilization. The free utilization of FGM technology helps alleviate the impact of social inequalities on glycemic control.

Keywords: Continuous glucose monitoring; Diabetes technology; Health inequalities; Socioeconomic deprivation; Socioeconomic status; T1D.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Blood Glucose
  • Blood Glucose Self-Monitoring
  • Diabetes Mellitus, Type 1* / complications
  • Diabetes Mellitus, Type 1* / epidemiology
  • Female
  • Follow-Up Studies
  • Glucose
  • Glycated Hemoglobin
  • Humans
  • Male
  • Middle Aged
  • Social Class

Substances

  • Blood Glucose
  • Glycated Hemoglobin
  • Glucose