Safety of e-cigarettes and nicotine patches as stop-smoking aids in pregnancy: Secondary analysis of the Pregnancy Trial of E-cigarettes and Patches (PREP) randomized controlled trial

Addiction. 2024 May;119(5):875-884. doi: 10.1111/add.16422. Epub 2024 Jan 17.

Abstract

Aims: The aim of this study was to examine the safety of e-cigarettes (EC) and nicotine patches (NRT) when used to help pregnant smokers quit.

Design: A recent trial of EC versus NRT reported safety outcomes in the randomized arms. We conducted a further analysis based on product use.

Setting: Twenty-three hospitals in England and a stop-smoking service in Scotland took part.

Participants: The participants comprised 1140 pregnant smokers.

Interventions: We compared women using and not using EC and NRT regularly during pregnancy.

Measurements: Measurements included nicotine intake compared with baseline, birth weight, other pregnancy outcomes, adverse events, maternal respiratory symptoms and relapse in early abstainers.

Findings: Use of EC was more common than use of NRT (47.3% vs 21.6%, P < 0.001). Women who stopped smoking (abstainers) and used EC at the end-of-pregnancy (EOP) reduced their salivary cotinine by 45% [49.3 ng/ml, 95% confidence interval (CI) = -79.8 to -10]. Only one abstainer used NRT at EOP. In dual users, cotinine increased by 19% (24 ng/ml, 95% CI = 3.5-68). In women reporting a reduction of at least 50% in cigarette consumption, cotinine levels increased by 10% in those using nicotine products and by 9% in those who did not. Birth weights in dual users and exclusive smokers were the same (3.1 kg). Birth weight in abstainers using either nicotine product was higher than in smokers [3.3 kg, standard deviation (SD) = 0.7] versus 3.1 kg, SD = 0.6; difference = 0.15 kg, 95% CI = 0.05-0.25) and not different from abstainers not using nicotine products (3.1 kg, SD = 0.8). Abstainers and smokers using nicotine products had no worse pregnancy outcomes or more adverse events than abstainers and smokers not using them. EC users reported more improvements than non-users in cough [adjusted relative risk (aRR) = 0.59, 95% CI = 0.37-0.93] and phlegm (aRR = 0.53, 95% CI = 0.31-0.92), controlling for smoking status. EC or NRT use had no association with relapse.

Conclusions: Regular use of e-cigarettes or nicotine patches by pregnant smokers does not appear to be associated with any adverse outcomes.

Keywords: Birth weight; e‐cigarettes; nicotine; pregnancy; safety; smoking; vaping.

Publication types

  • Randomized Controlled Trial

MeSH terms

  • Birth Weight
  • Cotinine
  • Electronic Nicotine Delivery Systems*
  • Female
  • Humans
  • Nicotine
  • Pregnancy
  • Recurrence
  • Smoking / adverse effects
  • Smoking Cessation*

Substances

  • Nicotine
  • Cotinine