Use of physician-modified inverted limb in conjunction with Zenith fenestrated stent graft to rescue failed previous endovascular and open repair

J Vasc Surg. 2024 May;79(5):1101-1109. doi: 10.1016/j.jvs.2023.12.013. Epub 2023 Dec 14.

Abstract

Objective: To evaluate outcomes and performance of inverted limbs (ILs) when used in conjunction with Zenith fenestrated stent grafts (Zfens) to treat patients with short distance between the lowest renal artery (RA) and aortic or graft bifurcation (A/GB).

Methods: This study was a multicenter, retrospective review of prospectively maintained database of patients with complex aortic aneurysms, failed endovascular aneurysm repair (EVAR), or open surgical repair (OSR) with short distance between LRA and A/GB treated using a combination of Zfen and an IL between 2013 and 2023. Endpoints included technical success, aneurysm sac regression, long-term device integrity, and target vessel patency. We defined technical success as implantation of the device with no endoleak, conversion to an aorto-uni-iliac or OSR.

Results: During this time, 52 patients underwent endovascular rescue of failed repair. Twenty (38.5%) of them required relining of the failed repairs using IL due to lowest RA to A/GB length restrictions. Two patients had undergone rescue with a fenestrated cuff alone but developed type III endoleaks. One patient with no previous implant had a short distance between the lowest RA and aortic bifurcation to accommodate the bifurcated distal device, and two patients had failed OSR or anastomotic pseudoaneurysms. The majority (94%) were men with a mean age of 76.8 ± 6.1 years. The mean aortic neck diameter and aneurysm size were 32 ± 4 cm and 7.2 ± 1.3 cm, respectively. The median time laps between initial repair and failure was 36 months (interquartile range [IQR], 24-54 months). Sixteen patients (80%) were classified as American Society of Anesthesiologists class III, whereas four were class IV. Seventy-eight vessels were targeted and successfully incorporated. Technical success was 100%, and median estimated blood loss was 100 mL (IQR, 100-200 mL). Mean fluoroscopy time and dose were 61 ± 18 minutes and 2754 ± 1062 mGy, respectively. Average hospital length of stay was 2.75 ± 2.15 days. Postoperative complication occurred in one patient who required lower extremity fasciotomy for compartment syndrome. At a median follow-up of 50 months (IQR, 18-58 months), there were no device migration, components separation, aneurysmal related mortality, and type I or type III endoleak. Aneurysm sac regression (95%) or stabilization (5%) was observed in all patients, including in four patients (25%) with type II endoleak.

Conclusions: The use of IL in conjunction with Zfen to treat patients with short distance between the lowest RA and A/GB is safe, effective, and has excellent long-term results. The technique expands the indication of Zfen, especially in patients with failed previous EVAR.

Keywords: Aortic disease progression; Endovascular repair; Endovascular rescue; Failed EVAR; Fenestrated and branched endograft; Type IA endoleak.

Publication types

  • Multicenter Study

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aortic Aneurysm, Abdominal* / diagnostic imaging
  • Aortic Aneurysm, Abdominal* / etiology
  • Aortic Aneurysm, Abdominal* / surgery
  • Blood Vessel Prosthesis
  • Blood Vessel Prosthesis Implantation*
  • Endoleak / etiology
  • Endoleak / surgery
  • Endovascular Procedures*
  • Female
  • Humans
  • Male
  • Physicians*
  • Prosthesis Design
  • Retrospective Studies
  • Risk Factors
  • Stents