Characteristics of ciliary muscle profile in high myopes measured by swept-source anterior segment optical coherence tomography

PLoS One. 2023 Nov 30;18(11):e0289135. doi: 10.1371/journal.pone.0289135. eCollection 2023.

Abstract

Objective: To characterize and compare the ciliary muscle thickness (CMT) between low and high myopes using swept-source anterior segment optical coherence tomography (AS-OCT).

Methods: Forty visually healthy young Chinese adults aged 18-25 years were divided into two groups based on refractive errors: low myopia (n = 20, spherical-equivalent refractive error (SER) between -0.50 D to -3.00 D) and high myopia (n = 20, SER ≤ -6.00 D). Cycloplegic refractions were performed before axial length (AL) and CMT were measured using a partial coherence laser interferometer and an AS-OCT respectively. CMT was measured perpendicularly to the sclera-ciliary muscle interface at 1 mm (CMT_1), 2 mm (CMT_2), and 3 mm (CMT_3) posterior to the scleral spur, and at the location with maximal thickness (CMT_MAX).

Results: High myopes demonstrated thicker CMT at 2 mm (CMT_2, p = 0.035) and 3 mm (CMT_3, p = 0.003) posterior to the scleral spur, but thinner maximal CMT (CMT_MAX, p = 0.005) than low myopes. The apical CMT_1 and CMT_MAX were also thinner in high myopes than in low myopes (both p< 0.001). CMT_MAX, apical CMT_1, and apical CMT_MAX correlated directly with SER and inversely with AL; in contrast, CMT_2 and CMT_3 showed inverse correlations with SER but direct correlations with AL.

Conclusion: Our findings revealed significant differences in CMT between low and high myopes, with high myopes showing thicker CMT at 2 mm and 3 mm posterior to the scleral spur, but thinner maximal CMT. These results provide new evidence of the potential structural differences in ciliary muscles during myopia development and progression.

MeSH terms

  • Adolescent
  • Adult
  • Ciliary Body / diagnostic imaging
  • Humans
  • Muscle, Smooth
  • Myopia* / diagnostic imaging
  • Refractive Errors*
  • Tomography, Optical Coherence / methods
  • Young Adult

Grants and funding

This work was supported by Innovation and Technology Commission InnoHK CEVR Project 1.5. Equipment and facilities needed for this study were provided by the Centre for Myopia Research and the Research Centre for SHARP Vision, The Hong Kong Polytechnic University. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript