Objectives: to evaluate the outcomes of Interval Copper Intrauterine Device (IUD) insertion performed by certified midwives and obstetric nurse practitioners at a Peri-Hospital Birth Center.
Methods: a cross-sectional study was conducted involving 75 women who underwent IUD insertion between January 2018 and February 2020. Data collection was carried out using medical records and telephone interviews.
Results: no instances of uterine perforation were observed. Expulsion rates of the devices were 1.3% within 30 to 45 days of use and 5.3% within the first year of use. The follow-up removal rate was 4.0%. The average pain score reported was 4.2 (SD = 3.3). Among those who continued using the device, 93.1% expressed satisfaction.
Conclusions: the findings demonstrate that IUD insertion by certified midwives and obstetric nurse practitioners is a safe procedure, yielding outcomes comparable to those reported in the existing literature.
Objetivos:: avaliar os desfechos da inserção do Dispositivo Intrauterino de Cobre de Intervalo por obstetrizes e enfermeiras obstetras em um Centro de Parto Normal Peri-hospitalar.
Métodos:: estudo transversal conduzido com 75 mulheres que tiveram o dispositivo inserido entre janeiro de 2018 e fevereiro de 2020. A coleta de dados foi realizada a partir de prontuários e contato telefônico.
Resultados:: não houve nenhuma perfuração uterina; 1,3% dos dispositivos foram expulsos com 30 a 45 dias de uso e 5,3% no primeiro ano de uso; a taxa de necessidade de remoção no retorno foi de 4,0%; e a pontuação média de dor foi 4,2 (DP = 3,3). Entre aquelas que ainda usavam o dispositivo, 93,1% se consideraram satisfeitas.
Conclusões:: a inserção do dispositivo por enfermeiras obstetras e obstetrizes mostrou ser segura, com desfechos similares aos observados na literatura.
Objetivos:: evaluar los resultados de la inserción del dispositivo intrauterino de cobre (DIU) realizado por matronas certificadas y enfermeras obstétricas especializadas en un Centro de Nacimientos Peri-Hospitalario.
Métodos:: se realizó un estudio transversal que incluyó a 75 mujeres sometidas a la inserción del DIU entre enero de 2018 y febrero de 2020. La recopilación de datos se realizó mediante registros médicos y entrevistas telefónicas.
Resultados:: no se observaron casos de perforación uterina. Las tasas de expulsión del dispositivo fueron del 1,3% en los primeros 30 a 45 días de uso y del 5,3% durante el primer año de uso. La tasa de retirada durante el seguimiento fue del 4,0%. La puntuación promedio del dolor informada fue de 4,2 (DE = 3,3). Entre aquellas que continuaron utilizando el dispositivo, el 93,1% manifestó satisfacción.
Conclusiones:: los hallazgos demuestran que la inserción del DIU por parte de matronas certificadas y enfermeras obstétricas especializadas es un procedimiento seguro, que produce resultados comparables a los reportados en la literatura existente.