Detection and Quantification of Acrylamide in Second Trimester Amniotic Fluid Using a Novel LC-MS/MS Technique to Determine Whether High Acrylamide Content during Pregnancy Is Associated with Fetal Growth

Biology (Basel). 2023 Nov 13;12(11):1425. doi: 10.3390/biology12111425.

Abstract

Introduction: Acrylamide, an organic compound, is, chemically speaking, a vinyl-substituted primary amide. It is produced industrially, principally as a precursor to polyacrylamides, for use in such products as plastics and cosmetics. This same compound, however, forms naturally in certain foods, both home-cooked and packaged, especially when prepared at high temperatures. We developed and validated a novel reliable technique for the determination of acrylamide in amniotic fluid. Multiple reaction monitoring (MRM) is a targeted mass spectrometry (MS) technique which enables the detection and quantification of particular molecules in a complex mixture. Thanks to its throughput, selectivity, and sensitivity, MRM-MS has been identified as offering an alternative to antibody-based studies for the purpose of biomarker verification. Our aim was to investigate the presence of acrylamide in amniotic fluid and, via the MRM-MS technique, to determine whether there is any correlation between maternal exposure to acrylamide, through a woman's diet, and fetal growth.

Methods: Our amniotic fluid bank included 40 samples from various fetal growth rates, as objectively denoted by the neonatal weight centile at delivery, while our analytical detection method was based on liquid chromatography-tandem mass spectrometry (LC-MS/MS). Acrylamide was determined with reversed phase chromatography and monitoring of two multiple reaction monitoring (MRM) transitions. Quantification was performed using the matrix-matched calibration curve.

Results: Acrylamide was detected at concentrations between 7.1 and 1468 ng/mL in six out of the total of 40 amniotic fluid samples that were used. Our method limit of detection and quantification was 1.4 ng/mL and 4.6 ng/mL, respectively. The repeatability of our method ranged between 11 and 14%, expressed as relative standard deviation levels between 5 and 100 ng/mL.

Conclusions: Detection of acrylamide in early second trimester amniotic fluid, for the first time in the literature to our knowledge, raises concerns about fetal health, given that published data on animal studies have attributed a number of birth defects to acrylamide. Our novel LC-MS/MS method for the determination of acrylamide in amniotic fluid proved to be effective and its performance in practice was very accurate, simple, and fast. Validation of the method revealed that the use of a matrix-matched curve is necessary for the quantification.

Keywords: LC-MS/MS; acrylamide; amniotic fluid; dietary exposure; fetal development; fetal growth restriction; food contaminant; liquid chromatography-tandem mass spectrometry; novel technique; small for gestational age (SGA); validation.

Grants and funding

The research received no external funding.