The effect of Fiber Optic RealShape technology on the reduction of radiation during complex endovascular surgery

J Vasc Surg. 2024 Apr;79(4):954-961. doi: 10.1016/j.jvs.2023.11.002. Epub 2023 Nov 4.

Abstract

Objective: Despite the advantages that fenestrated endovascular aortic repair has over open repair, it is accompanied by the consequence of radiation exposure, which can result in long-term complications for both the patient and surgical staff. Fiber Optic RealShape (FORS) technology is a novel advancement that uses emitted light from a fiber optic wire and enables the surgeon to cannulate vessels in real time without live fluoroscopy. This technology has been implemented at select centers to study its effectiveness for cannulation of target vessels and its impact on procedural radiation.

Methods: We collected prospective data on physician-modified endograft (PMEG) cases before and after the introduction of FORS technology. FORS PMEGs were matched with up to three conventional fluoroscopy cases by number of target vessels, inclusion of a bifurcated device below, aneurysm extent, and patient body mass index. The procedural radiation parameters were compared between these cohorts. Within the FORS cohort, we analyzed the rate of successful target vessel cannulation for all cases done with this technology (including cases other than PMEGs), and we compared the radiation between the cannulations using only FORS with those that abandoned FORS for conventional fluoroscopy.

Results: Nineteen FORS PMEGs were able to be matched to 45 conventional fluoroscopy cases. Procedures that used FORS technology had significantly reduced total air kerma (527 mGy vs 964 mGy), dose area product (121 Gy∗cm2 vs 186 Gy∗cm2), fluoroscopy dose (72.1 Gy∗cm2 vs 132.5 Gy∗cm2), and fluoroscopy time (45 minutes vs 72 minutes). There was no difference in procedure length, total contrast, or digital subtraction angiography. Within FORS cases, 66% of cannulations were completed using only FORS. Cannulations using only FORS had significant reduction of navigation air kerma (5.0 mGy vs 26.5 mGy), dose area product (1.2 Gy∗cm2 vs 5.1 Gy∗cm2), and fluoroscopy time (0.6 minutes vs 2.3 minutes) compared with cannulations abandoning FORS for conventional fluoroscopy.

Conclusions: This study demonstrates the advantages of FORS for total procedural radiation as well as during individual cannulation tasks. The implementation of FORS for target vessel catheterization has the potential to decrease the total degree of radiation exposure for the patient and surgical staff during complex endovascular aortic surgeries.

Keywords: FORS; Fiber optics; PMEG; Radiation.

MeSH terms

  • Aortography / methods
  • Blood Vessel Prosthesis Implantation*
  • Endovascular Procedures*
  • Fluoroscopy
  • Humans
  • Prospective Studies
  • Radiation Dosage
  • Radiation Exposure* / adverse effects
  • Radiation Exposure* / prevention & control
  • Retrospective Studies
  • Technology
  • Treatment Outcome