Outcomes of Exeter cemented total hip arthroplasty in a county hospital: survivorship of eight hundred and ninety four hips with a minimum ten-year follow up

Int Orthop. 2024 Mar;48(3):729-735. doi: 10.1007/s00264-023-06026-y. Epub 2023 Nov 2.

Abstract

Purpose: A total of 894 hips were evaluated to describe the survivorship of Exeter cemented femoral stems and report the outcomes and complications of our 'Exeter- era', and there is no study from Central or Eastern Europe demonstrating similar results.

Methods: Between January 2000 and December 2009, a total of 894 hips were included who underwent Exeter universal and V40 femoral stems with a mean follow up of 13 years. Cemented Exeter low profile polyethylene cups were used in 889 patients (99.4%) cups. Harris hip score (HHS) was used and statistical outcome measures were calculated with revision as an endpoint for aseptic loosening of the stem, aseptic loosening of any component, all-cause revision of the stem, and all-cause revision of the hip.

Results: A total of 103 patients died and 129 (14.4%) operated hips were lost to follow-up before ten years. Out of the 662, ten stems (1.5%) were revised for aseptic loosening. Aseptic loosening of any component was the reason for revision in 43 cases (6.5%), consisting of 40 cup revisions and ten stem exchanges. Periprosthetic fracture occurred in 17 cases (1.9%) Periprosthetic joint infection occurred in 18 cases (2.01%). Three cups were exchanged for recurrent dislocation, and two stems had broken.

Conclusion: Exeter hip system has provided reproducible results across different centres worldwide, as it did in our series. Thorough surgical and cementing technique is of utmost importance for achieving these results. The cup is the weak point of the system and use of a hybrid system is worth considering.

Keywords: Cemented THA; Exeter; V40 femoral stem.

MeSH terms

  • Arthroplasty, Replacement, Hip* / adverse effects
  • Follow-Up Studies
  • Hip Prosthesis* / adverse effects
  • Hospitals, County
  • Humans
  • Polyethylene
  • Prosthesis Design
  • Prosthesis Failure
  • Reoperation
  • Survivorship

Substances

  • Polyethylene