Recurrent hepatic artery pseudoaneurysm repair with overlapping tapered stent-graft technique

Radiol Case Rep. 2023 Oct 17;18(12):4537-4543. doi: 10.1016/j.radcr.2023.09.038. eCollection 2023 Dec.

Abstract

Hepatic artery pseudoaneurysms (HAPs) are rare but life-threatening complications associated with hepatic artery infusion pump (HAIP) therapy for unresectable liver metastases. Traditional management options include open surgery or stent placement, but these approaches have drawbacks. We present a unique case of a dislodged stent embedded in a HAP, resulting in delayed type-I endoleak. To address this, we employed a novel technique using multiple overlapping tapered stents to reconstruct the hepatic artery. This approach successfully excluded the pseudoaneurysm without endoleak. Stent-graft placement emerges as a safer and more effective option for managing HAP, preserving hepatic arterial flow, and reducing morbidity compared to other methods. However, further research is needed to evaluate this technique's long-term outcomes and potential complications.

Keywords: Covered stent; Hepatic artery infusion pump; Hepatic artery pseudoaneurysm; Multiple overlapping tapered stents; Pseudoaneurysm stenting; Stent-graft.

Publication types

  • Case Reports