Clinical Impact of Patient-Prosthesis Mismatch After Aortic Valve Replacement With a Mechanical or Biological Prosthesis

Tex Heart Inst J. 2023 Oct 18;50(5):e228048. doi: 10.14503/THIJ-22-8048.

Abstract

Background: Patient-prosthesis mismatch (PPM) may impair functional capacity and survival after aortic valve replacement. This study aimed to investigate the impact of PPM on long-term survival and quality of life after mechanical and biological aortic valve replacement.

Methods: This study included 595 consecutive patients who had undergone isolated aortic valve replacement. Patients were divided into 2 groups according to prosthesis type. The baseline and operative characteristics, survival rates, complications, and quality of life of the groups with and without PPM were compared for up to 6 years. The PPM calculation was performed using the effective orifice area value provided by the manufacturer divided by the patient's body surface area.

Results: The moderate to severe PPM rates were 69.8% and 3.7% after biological and mechanical prosthesis implantation, respectively. Mean survival for patients in the biological group who had PPM was statistically significantly shorter (50.2 months [95% CI, 45.2-55.3]) than for patients in the biological group without PPM (60.1 months [95% CI, 55.7-64.4]; P = .04). In the mechanical prosthesis group, there was no difference in mean survival between the subgroup with PPM (66.6 months [95% CI, 58.3-74.9]) and the subgroup without PPM (64.9 months [95% CI, 62.6-67.2]; P = .50). A quality-of-life questionnaire's scores did not differ between the groups.

Conclusion: Mismatch is common after biological valve implantation and statistically significantly affects long-term survival and quality of life. If the risk of PPM after implantation of a biological prosthesis is suspected, adopting strategies to avoid PPM at the time of surgery is warranted.

Keywords: Patient outcome assessment; aortic valve disease; bioprosthesis; heart valve prosthesis implantation; quality of life.

MeSH terms

  • Aortic Valve / diagnostic imaging
  • Aortic Valve / surgery
  • Aortic Valve Stenosis* / surgery
  • Heart Valve Prosthesis Implantation* / adverse effects
  • Heart Valve Prosthesis*
  • Humans
  • Prosthesis Design
  • Quality of Life
  • Risk Factors
  • Treatment Outcome

Grants and funding