Mechanical compression management of the right middle cerebral artery inferior trunk using a stent during coil embolization of middle cerebral artery aneurysms: A case report and literature review

J Interv Med. 2023 Jan 12;6(3):126-129. doi: 10.1016/j.jimed.2022.10.004. eCollection 2023 Aug.

Abstract

Endovascular coil embolization is a minimally invasive, rapid, and effective method for the treatment of intracranial aneurysms. However, complications associated with coil embolization, such as intraoperative aneurysm rupture or arterial occlusion, should be promptly managed during the procedure to avoid catastrophic consequences. This study presents a case of mechanical compression management of the right middle cerebral artery (MCA) inferior trunk during coil embolization for bilateral MCA aneurysms. The inferior trunk of the right MCA was abruptly occluded due to mechanical compression during coil embolization of the right MCA bifurcation aneurysm. A Solitaire AB stent (4 ​× ​20 mm, Covidien/Medtronic, Dublin, Ireland) was implanted in the inferior trunk of the right MCA after tirofiban was injected via a microcatheter, and the right inferior trunk was recanalized. The patient also underwent coil embolization of the left MCA bifurcation aneurysm, without any complications. It is crucial to recognize compressive occlusion of adjacent aneurysm branches to avoid severe complications during intracranial aneurysm embolization. Stent placement is a rescue treatment option for recanalization of an occluded artery.

Keywords: Endovascular coil embolization; Intracranial aneurysm; Mechanical compression; Stent.

Publication types

  • Case Reports