Similarities and discrepancies between commercially available bioelectrical impedance analysis system and dual-energy X-ray absorptiometry for body composition assessment in 10-14-year-old children

Sci Rep. 2023 Oct 13;13(1):17420. doi: 10.1038/s41598-023-44217-0.

Abstract

A variety of easy-to-use commercial bioelectrical impedance appliances are available. The aim of this study was to examine the usefulness of a commercially available body composition meter using bioelectrical impedance analysis (BIA) by comparing its measurement results with those obtained from dual-energy X-ray absorptiometry (DXA). The participants were 443 children aged from 10 to 14 years (226 boys and 217 girls). Fat mass, fat-free mass, lean body mass, percentage of body fat, and bone mineral contents were evaluated for all participants using BIA and DXA. The agreement in the anthropometric data obtained from both devices was analyzed using correlation analysis, intraclass correlation coefficient (ICC), Lin's concordance correlation coefficient (CCC), Bland-Altman plots, and ordinary least products regression analysis. Equivalence between both devices was tested by two one-sided t-test. All measured indicators showed strong linear correlations between the two measurement systems (r, 0.853-1.000). Fat mass, fat-free mass, and lean body mass showed absolute concordance (ICC, 0.902-0.972; Lin's CCC, 0.902-0.972). BIA overestimated bone mineral content (62.7-66.5%) and underestimated percentage of body fat (- 8.9 to - 0.8%), lean body mass (- 3.5 to - 1.8%), and body mass (- 0.8 to - 0.5%). For fat mass and fat-free mass, the overestimate or underestimate varied according to the sex and statistical analysis test. Bland-Altman analysis and ordinary least products analysis showed fixed bias and proportional bias in all indicators. Results according to quartiles of body mass index showed poor agreement for fat mass and percentage of body fat in both boys and girls in the lowest body mass index quartile. The present results revealed strong linear correlations between BIA and DXA, which confirmed the validity of the present single-frequency BIA-derived parameters. Our results suggest that BIA cannot provide the exact same values as DXA for some body composition parameters, but that performance is sufficient for longitudinal use within an individual for daily health management and monitoring.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Absorptiometry, Photon / methods
  • Adipose Tissue / diagnostic imaging
  • Adolescent
  • Anthropometry
  • Body Composition
  • Body Mass Index
  • Breast Neoplasms*
  • Child
  • Electric Impedance
  • Female
  • Humans
  • Male
  • Precancerous Conditions*