Midpoint of C7 Lateral Mass Serves as an Accurate Reference Point for the Placement of T1 Pedicle Screws: An Anatomic Study

Oper Neurosurg (Hagerstown). 2024 Mar 1;26(3):323-329. doi: 10.1227/ons.0000000000000950. Epub 2023 Oct 12.

Abstract

Background and objectives: Free-hand placement of T1 pedicle screws can often be challenging. A reliable free-hand technique for placement of T1 pedicle screws can overcome some of the difficulties associated with poor fluoroscopy in this region. The purpose of this study was to propose a novel anatomic landmark for accurate identification of the T1 entry point using the midpoint of the C7 lateral mass as a reference point. Our hypothesis is that the midpoint of the C7 lateral mass is within 1-2 mm of the center of the T1 pedicle.

Methods: Using 3-dimensional reconstruction software, the pedicle of T1 and the lateral mass of C7 were isolated to assess the location of the T1 pedicle relative to the C7 lateral mass. Specifically, the distance between the center of the T1 pedicle and the center of the C7 lateral mass was measured on 40 computed tomography scans. Furthermore, a clinical validation of this technique was performed by assessing the postoperative computed tomography scans of 53 patients undergoing cervicothoracic instrumentation. The Gertzbein and Robbins classification system was used to grade the accuracy of T1 pedicle screw placements in all patients using this technique.

Results: The average horizontal deviation + SD from centers of the T1 pedicle and the C7 lateral mass was 0.398 mm ± 0.953 mm. The T1 pedicle on average was slightly medial to the center of the C7 lateral mass. A total of 98.1% of T1 pedicle screws placed in vivo using the free-hand technique were of Grade A.

Conclusion: In this article, we demonstrate that the center of the C7 lateral mass overlays the T1 pedicle and the optimal entry point is immediately below the midpoint of the C7 lateral mass. This approach provides a practical and accurate landmark in posterior cervicothoracic spine procedures that reduce the need for additional radiation exposure or increased operative time with image-guided techniques.

MeSH terms

  • Cervical Vertebrae / diagnostic imaging
  • Cervical Vertebrae / surgery
  • Fluoroscopy
  • Humans
  • Pedicle Screws*
  • Spinal Fusion* / methods
  • Tomography, X-Ray Computed