Implant breakage after shoulder arthroplasty: a systematic review of data from worldwide arthroplasty registries and clinical trials

BMC Musculoskelet Disord. 2023 Oct 11;24(1):804. doi: 10.1186/s12891-023-06922-9.

Abstract

Background: Implant breakage after shoulder arthroplasty is a rare complication after aseptic loosening, infection or persistent pain, resulting in malfunction of the components requiring revision surgery. This correlates with a high burden for the patient and increasing costs. Specific data of complication rates and implant breakage are available in detailed arthroplasty registries, but due to the rare occurrence and possibly underestimated value rarely described in published studies. The aim of this systematic review was to point out the frequency of implant breakage after shoulder arthroplasty. We hypothesized that worldwide arthroplasty registry datasets record higher rates of implant breakage than clinical trials.

Methods: PubMed, MEDLINE, EMBASE, CINHAL, and the Cochrane Central Register of Controlled Trials database were utilized for this systematic review using the items "(implant fracture/complication/breakage) OR (glenoid/baseplate complication/breakage) AND (shoulder arthroplasty)" according to the PRISMA guidelines on July 3rd, 2023. Study selection, quality assessment, and data extraction were conducted according to the Cochrane standards. Case reports and experimental studies were excluded to reduce bias. The breakage rate per 100,000 observed component years was used to compare data from national arthroplasty registries and clinical trials, published in peer-reviewed journals. Relevant types of shoulder prosthetics were analyzed and differences in implant breakage were considered.

Results: Data of 5 registries and 15 studies were included. Rates of implant breakage after shoulder arthroplasty were reported with 0.06-0.86% in registries versus 0.01-6.65% in clinical studies. The breakage rate per 100,000 observed component years was 10 in clinical studies and 9 in registries. There was a revision rate of 0.09% for registry data and 0.1% for clinical studies within a 10-year period. The most frequently affected component in connection with implant fracture was the glenoid insert.

Conclusion: Clinical studies revealed a similar incidence of implant failure compared to data of worldwide arthroplasty registries. These complications arise mainly due to breakage of screws and glenospheres and there seems to be a direct correlation to loosening. Periprosthetic joint infection might be associated with loosening of the prosthesis and subsequent material breakage. We believe that this analysis can help physicians to advise patients on potential risks after shoulder arthroplasty.

Level of evidence: III.

Keywords: Implant breakage; Implant fracture; Reversed shoulder arthroplasty; Shoulder arthroplasty; Total shoulder arthroplasty.

Publication types

  • Systematic Review

MeSH terms

  • Arthroplasty, Replacement, Shoulder* / adverse effects
  • Arthroplasty, Replacement, Shoulder* / methods
  • Humans
  • Postoperative Complications / epidemiology
  • Postoperative Complications / etiology
  • Prosthesis Failure
  • Prosthesis Implantation / adverse effects
  • Registries
  • Reoperation / adverse effects
  • Shoulder Joint* / surgery
  • Shoulder Prosthesis* / adverse effects
  • Treatment Outcome