Surgical management of neck of femur fractures in patients younger than sixty-five years: a comparative study of three fixation methods

Int Orthop. 2023 Dec;47(12):3099-3106. doi: 10.1007/s00264-023-05997-2. Epub 2023 Oct 6.

Abstract

Purpose: Several surgical implants have been used for the treatment of neck of femur fracture (NOF) in younger patients such as dynamic hip screw (DHS) and cannulated compression screw. However, the superiority of one or another osteosynthesis device remains a matter of debate. The aim of this work is to evaluate and compare three fixation modalities: Cannulated Hip Screws (CHS), DHS and DHS associated to anti-rotating screw for surgical treatment of femoral neck fracture in young adults.

Methods: It is a retrospective comparative study of three series of NOF fractures treated surgically over a period of ten years; including young adult patients (age > 18 years and < 65 years) treated conservatively using closed or open reduction and internal fixation. All types of NOF fractures according to Garden classification were included. Pathological, basi-cervical fractures and fractures on previously operated hips were excluded. The minimum follow-up recommended was two years. Clinical evaluation was based on the Postel Merle d'Aubigné score (PMA), the visual analogue scale (VAS), the Parker score, and the Hip Disability and Osteoarthritis Outcome Score (HOOS score). Reduction quality was assessed on X-rays.

Results: Our series included 72 patients that were divided in three groups: Group A: Fixation using cannulated hip screws (33 patients). Group B: Fixation using DHS only (21 patients). Group C: Fixation using DHS associated to anti-rotation screw (18 patients). The patients of group A had better PMA and VAS scores, but there was no statistically significant difference. However, a significant difference (p=0.001) was found for the HOOS score. The fractures treated with DHS associated with anti-rotating screws, had the highest loss of reduction in the vertical axis (Yp) with the highest femoral head collapse (Zp) values. Group A had the lowest loss of reduction in the horizontal axis (Xp). There was no significant difference between the three methods of osteosynthesis in terms of loss of correction though.

Conclusion: We found comparable results in terms of healing and complication rates and loss of reduction for the three groups with no significant difference. However, the HOOS score was significantly better in the cannulated hip screw group.

Keywords: Cannulated compression screw; Complications; Dynamic hip screw; Femoral neck fracture; Young patient.

MeSH terms

  • Adult
  • Bone Screws
  • Femoral Fractures*
  • Femoral Neck Fractures* / surgery
  • Femur / pathology
  • Fracture Fixation, Internal / methods
  • Humans
  • Middle Aged
  • Retrospective Studies
  • Treatment Outcome
  • Young Adult