Possible depth-resolved reconstruction of shear moduli in the cornea following collagen crosslinking (CXL) with optical coherence tomography and elastography

Biomed Opt Express. 2023 Sep 1;14(9):5005-5021. doi: 10.1364/BOE.497970.

Abstract

Corneal collagen crosslinking (CXL) is commonly used to prevent or treat keratoconus. Although changes in corneal stiffness induced by CXL surgery can be monitored with non-contact dynamic optical coherence elastography (OCE) by tracking mechanical wave propagation, depth dependent changes are still unclear if the cornea is not crosslinked through the whole depth. Here, phase-decorrelation measurements on optical coherence tomography (OCT) structural images are combined with acoustic micro-tapping (AµT) OCE to explore possible reconstruction of depth-dependent stiffness within crosslinked corneas in an ex vivo human cornea sample. Experimental OCT images are analyzed to define the penetration depth of CXL into the cornea. In a representative ex vivo human cornea sample, crosslinking depth varied from ∼100 µm in the periphery to ∼150 µm in the cornea center and exhibited a sharp in-depth transition between crosslinked and untreated areas. This information was used in an analytical two-layer guided wave propagation model to quantify the stiffness of the treated layer. We also discuss how the elastic moduli of partially CXL-treated cornea layers reflect the effective engineering stiffness of the entire cornea to properly quantify corneal deformation.

Associated data

  • figshare/10.6084/m9.figshare.23929626