Abstract

Background: A novel method to measure atrial fibrillation cycle length (AF-CL) was recently described, based on the average of 10 consecutive signals (FARS10). FARS10 accurately identified pulmonary vein isolation (PVI)-responders among patients with persistent AF. Whether this method is applicable to patients with paroxysmal AF is unknown.

Objective: The aim of this study is to evaluate the prognostic value of FARS10 measurements in patients with paroxysmal AF.

Methods and results: We enrolled paroxysmal AF patients undergoing PVI in a prospective multicenter study. After AF induction with a standardized protocol, the AF-CL was measured using FARS-10 method. The primary endpoint was AF/AT-recurrence. One-hundred and four patients were included (61 ± 14 years, 25% females). After a mean follow-up of 12 ± 4 months, AF/AT recurrence rate was 20%. The fastest PV CL (fPV-CL) was independently associated with the primary endpoint at multivariate analysis (HR 1.02, p < 0.001). Every 10 ms increase in fPV-CL, AF recurrences increased by 20%. The value of 160 ms was found to be the optimal cut-off (specificity 81%, sensitivity 76%). Patients with fPV-CL < 160 ms experienced lower AF recurrences as compared to patients with fPV-CL > 160 ms (8% vs. 32% at 1 year; HR = 0.17, p < 0.001). Progression to persistent AF was observed in 13% of patients with fPV-CL > 160 ms.

Conclusion: fPV-CL measured with the FARS-10 method accurately predicts PVI success in paroxysmal AF patients undergoing PVI. Patients with slow PV activity (fPV-CL > 160 ms) experience higher AF recurrence rate after PVI and more frequent progression to persistent AF. In 104 patients with paroxysmal atrial fibrillation (AF) undergoing AF ablation, AF was induced at the beginning of the procedure. Pulmonary vein activity was measured using FARS10 measurement (10 consecutive fastest atrial repetitive similar morphology signals). The value of 160 ms was found to be the best cut-off to discriminate outcomes. At 1-year follow-up, patients with fast veins (< 160 ms) experienced significantly fewer AF recurrences as compared to patients with slow veins (> 160 ms). PV activity measured with FARS10 method accurately discriminates pulmonary vein isolation responders, in patients with paroxysmal AF.

Abbreviations: AF atrial fibrillation, AT atrial tachycardia, CL cycle length, FARS10: 10 consecutive fastest atrial repetitive similar morphology signal, fPV fastest pulmonary vein, HR hazard ratio, ms milliseconds.

Keywords: Atrial fibrillation; Cycle length; Paroxysmal; Pulmonary vein activity; Pulmonary vein isolation; Responder.